4.7 Article

Development of in-aquifer heat testing for high resolution subsurface thermal-storage capability characterisation

Journal

JOURNAL OF HYDROLOGY
Volume 534, Issue -, Pages 113-123

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jhydrol.2015.12.013

Keywords

Distributed-temperature-sensing; Shallow subsurface thermal-storage; Shallow geothermal exploration; Direct-push in situ investigations

Funding

  1. German Federal Environmental Foundation - DBU
  2. German Ministry of Education and Research - BMBF [03EK3022B]

Ask authors/readers for more resources

The ongoing transition from fossil fuels to alternative energy source provision has resulted in increased geothermal uses as Well as storage of the shallow subsurface. Existing approaches for exploration of shallow subsurface geothermal energy storage often lack the ability to provide information concerning the spatial variability of thermal storage parameters. However, parameter distributions have to be known to ensure that sustainable geothermal use of the shallow subsurface can take place especially when it is subject to intensive usage. In this paper, we test a temperature decay time approach to obtain in situ, direct, qualitative, spatial high-resolution information about the distribution of thermal storage capabilities of the shallow subsurface. To achieve this, temperature data from a high-resolution Fibre Optic-Distributed-Temperature-Sensing device, as well as data from conventional Pt-100-temperature-sensors were collected during a heat injection test. The latter test was used to measure the decay time of temperature signal dissipation of the subsurface. Signal generation was provided by in-aquifer heating with a temperature self-regulating electric heating cable. Heating was carried out for 4.5 days. After this, a cooling period of 1.5 weeks was observed. Temperature dissipation data was also compared to Direct Push-derived high-resolution (hydro-)geological data. The results show that besides hydraulic properties also the bedding and compaction state of the sediment have an impact on the thermal storage capability of the saturated subsurface. The temperature decay time approach is therefore a reliable method for obtaining information regarding the qualitative heat storage capability of heterogeneous aquifers for the use with closed loop system geothermal storage systems. Furthermore, this approach is advantageous over other commonly used methods, e.g. soil-sampling and laboratory analysis, as even small changes in (hydro-)geological properties lead to strong variances in observed heat-storage capabilities at the investigated case study site. By using fibre-optic-thermometers, nearly every requested spatial resolution can be achieved and easily be adjusted to the needs of actual test sites for shallow geothermal storage exploration. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available