4.5 Article

Multiphysics Simulation of the NASA SIRIUS-CAL Fuel Experiment in the Transient Test Reactor Using Griffin

Journal

ENERGIES
Volume 15, Issue 17, Pages -

Publisher

MDPI
DOI: 10.3390/en15176181

Keywords

griffin; multiphysics; transient; TREAT; SIRIUS; NASA; validation; MOOSE

Categories

Funding

  1. U.S. Department of Energy [DE-AC07-05ID14517]
  2. NASA Space Technology Mission Directorate (STMD)

Ask authors/readers for more resources

NASA is restarting efforts to develop nuclear thermal propulsion for interplanetary missions, focusing on advanced materials and fabrication methods. Simulation results of SIRIUS-CAL calibration experiment in TREAT showed successful matching of reactor power transient, but further reduction of uncertainty range is necessary.
After approximately 50 years, NASA is restarting efforts to develop nuclear thermal propulsion (NTP) for interplanetary missions. Building upon nuclear engine tests performed from the late 1950s to the early 1970s, the present research and testing focuses on advanced materials and fabrication methods. A number of transient tests have been performed to evaluate materials performance under high-temperature, high-flux conditions, with several more experiments in the pipeline for future testing. The measured data obtained from those tests are being used to validate the Griffin reactor multiphysics code for this particular type of application. Griffin was developed at Idaho National Laboratory (INL) using the MOOSE framework. This article describes the simulation results of the SIRIUS-CAL calibration experiment in the Transient Reactor Test Facility (TREAT). SIRIUS-CAL was the first transient test conducted on NASA fuels, and although the test was performed with a relatively low core peak power, the test specimen survived a temperature exceeding 900 K. Griffin simulations of the experiment successfully matched the reactor's power transient after calibrating the initial control rod position to match the initial reactor period. The thermal-hydraulics model largely matches the time-dependent response of a thermocouple located within the experiment specimen to within the uncertainty estimate. However, the uncertainty range is significant and must be reduced in the future.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available