4.5 Article

Measuring and Predicting the In-Ground Temperature Profile for Geothermal Energy Systems in the Desert of Arid Regions

Journal

ENERGIES
Volume 15, Issue 19, Pages -

Publisher

MDPI
DOI: 10.3390/en15197268

Keywords

desert; arid climate; geothermal energy; in-ground temperature; prediction; heat storage

Categories

Funding

  1. Deputyship for Research and Innovation, Ministry of Education in Saudi Arabia [DRI-KSU-542]

Ask authors/readers for more resources

This study provides a theoretical basis for using geothermal energy in the Arabian Peninsula desert to solve air conditioning and heating problems by measuring the changes in underground temperature. The results show that the underground temperature increases with depth and varies seasonally, and the use of earth-to-air heat exchangers can effectively utilize this temperature difference to solve the energy problem in this region.
Instead of fossil fuels, clean renewable energy resources are being used to meet space heating and cooling needs, to reduce global warming and air pollution worldwide. In the desert of the Arabian Peninsula, extensive solar irradiance and drastic variations in air temperatures (daily and/or seasonally) are common; thus, geothermal energy resources are a promising solution that is nearly independent of weather fluctuations. Due to a lack of information about in-ground temperature profiles in these regions, the use of geothermal energy resources for domestic applications is very limited. Therefore, this study aimed to measure the in-ground temperature (T-g) up to 3.5 m in depth for one year. Due to the difficulty of digging in the ground (i.e., gravelly sand; rocky, dry soil), numerical equations were adopted and used to simulate the in-ground temperature (T-g) for a depth > 3 m. These equations were validated by comparing the measured and simulated values of T-g for depths <= 3 m under extreme weather conditions. The validation yielded a mean absolute error (E-MA) of <= 1.2 degrees C and a root mean square error (E-RMS) of <= 1.42 degrees C. The measurements showed that at 3 m depth, the in-ground temperature was 32 degrees C in summer and 29 degrees C in winter. The simulation showed that values of T-g increased with depth in winter and decreased in summer and became constant as 30 degrees C at 13 m depth throughout the year (i.e., the undisturbed ground temperature (UGT)). This temperature would provide considerable heating and cooling capacity if an earth-to-air heat exchanger were implemented in arid regions where ambient temperatures exceed 47 degrees C on summer days and drop below 10 degrees C on winter nights. The theoretical prediction of T-g using the proposed equations is a useful tool for designers who use geothermal effects for indoor space cooling and heating in the desert of arid regions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available