4.5 Article

Pseudo-outbreaks of Stenotrophomonas maltophilia on an intensive care unit in England

Journal

JOURNAL OF HOSPITAL INFECTION
Volume 92, Issue 4, Pages 392-396

Publisher

W B SAUNDERS CO LTD
DOI: 10.1016/j.jhin.2015.12.014

Keywords

Bronchoscope; Contamination; Intensive care unit; Pseudo-outbreak; Stenotrophomonas maltophilia

Ask authors/readers for more resources

Background: In June 2014, a cluster of identical S. maltophilia isolates was reported in an adult intensive care unit (ICU) at a district general hospital. An outbreak control team was convened to investigate the cluster and inform control measures. Aim: To identify potential risk factors for isolation of S. maltophilia in this setting. Methods: We conducted a cohort study of ICU patients for whom a bronchoalveolar lavage (BAL) specimen was submitted between October 2013 and October 2014. Cases were patients with S. maltophilia-positive BAL. We calculated the association between isolation of S. maltophilia and patient characteristics using risk ratios (RRs) with 95% confidence intervals (95% CIs) and univariate logistic regression. Chi-squared or Fisher's exact tests were used. BAL specimens were microbiologically typed using pulse-field gel electrophoresis (PFGE). Findings: Eighteen patients met the case definition. Two patients had clinical presentations that warranted antibiotic treatment for S. maltophilia. All cases were exposed to bronchoscopy. PFGE typing revealed clusters of two strain types. We found statistically significant elevated risks of isolating BRISPOSM-4 in patients exposed to bronchoscope A (RR: 13.56; 95% CI: 1.82-100; P < 0.001) and BRISPOSM-3 in patients exposed to bronchoscope B (RR: 16.89; 95% CI: 2.14-133; P < 0.001). S. maltophilia type BRISPOSM-4 was isolated in water used to flush bronchoscope A after decontamination. Conclusion: Two pseudo-outbreaks occurred in which BAL specimens had been contaminated by reusable bronchoscopes. We cannot exclude the potential for colonization of the lower respiratory tract of exposed patients. Introduction of single-use bronchoscopes was an effective control measure. Crown Copyright (C) 2016 Published by Elsevier Ltd on behalf of the Healthcare Infection Society. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available