4.7 Article

Comparison and analysis of energy loss and flow characteristics of T-junctions via secondary flow and entropy production

Journal

BUILDING AND ENVIRONMENT
Volume 225, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2022.109635

Keywords

T-junction; Energy loss reduction; Secondary flow; Entropy production; Guide vane

Funding

  1. Research and Development Project of the Ministry of Housing and Urban -Rural Development of the People?s Republic of China
  2. [K20200603]

Ask authors/readers for more resources

This study proposes a method to reduce energy loss and resistance by inserting guide vanes in a confluent T-junction, and analyzes the flow characteristics and energy loss distribution through experiments and simulations. The results show that the T-junction with curved guide vanes has significantly smaller energy loss coefficient compared to the traditional T-junction.
The energy loss and resistance effect of traditional local components widely used in HVAC systems in buildings are severe. To improve the significant energy loss effect, a method to reduce resistance and energy loss by inserting guide vanes in a confluent T-junction is proposed through full-scale experiments and numerical sim-ulations, and the flow characteristics and energy loss distribution of the T-junction are analysed through the swirl intensity of the secondary flow and the entropy production principle. The energy loss reduction rates (ELRRs) of T-junctions are compared under different diameter ratios, branch angles, and flow ratios. The results show that the total energy loss coefficient of the T-junction with curved guide vanes is significantly smaller than that of the traditional T-junction. The maximum ELRR is 43.5% when the diameter ratio is 0.8 and the flow ratio is 0.2. The insertion of a guide vane cuts the large vortex into multiple small vortices, thereby weakening the entropy production and swirl intensity of the downstream secondary flow. Under different Reynolds numbers, the effect of the guide vane on reducing the resistance and energy loss of the T-junction is verified by full-scale experi-ments, and the experimental results are in excellent agreement with the simulation results. This study provides data support and a reference for the standardized and design of low-energy loss T-junctions in HVAC systems for the energy-saving operation of buildings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available