4.5 Article

Sleep postures monitoring based on capacitively coupled electrodes and deep recurrent neural networks

Journal

BIOMEDICAL ENGINEERING ONLINE
Volume 21, Issue 1, Pages -

Publisher

BMC
DOI: 10.1186/s12938-022-01031-5

Keywords

Capacitively coupled electrode; Sleep posture; Capacitive electrocardiogram; Recurrent neural network

Funding

  1. Shanghai Committee of Science and Technology [20S31903900]
  2. Greater Bay Area Institute of Precision Medicine (Guangzhou) [IPM2021C011]
  3. Shanghai Municipal Science and Technology International R&D Collaboration Project [20510710500]
  4. National Natural Science Foundation of China [62001118]

Ask authors/readers for more resources

This study investigates another potential application of cECG in sleep monitoring, specifically sleep posture recognition. By using a classifier model based on a deep recurrent neural network, accurate recognition of different sleep postures was achieved.
Background Capacitively coupled electrode (CC electrode), as a non-contact and unobtrusive technology for measuring physiological signals, has been widely applied in sleep monitoring scenarios. The most common implementation is capacitive electrocardiogram (cECG) that could provide useful clinical information for assessing cardiac function and detecting cardiovascular diseases. In the current study, we sought to explore another potential application of cECG in sleep monitoring, i.e., sleep postures recognition. Methods Two sets of experiments, the short-term experiment, and the overnight experiment, were conducted. The cECG signals were measured by a smart mattress based on flexible CC electrodes and sleep postures were recorded simultaneously. Then, a classifier model based on a deep recurrent neural network (RNN) was proposed to distinguish sleep postures (supine, left lateral and right lateral). To verify the reliability of the proposed model, leave-one-subject-out cross-validation was introduced. Results In the short-term experiment, the overall accuracy of 96.2% was achieved based on 30-s segment, while the overall accuracy was 88.8% using one heart beat segment. For the unconstrained overnight experiment, the accuracy of 91.0% was achieved based on 30-s segment, while the accuracy was 81.4% using one heart beat segment. Conclusions The results suggest that cECG could render valuable information about sleep postures detection and potentially be helpful for sleep disorder diagnosis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available