4.7 Article

An effective method based on simulated annealing for automatic generation control of power systems

Journal

APPLIED SOFT COMPUTING
Volume 126, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.asoc.2022.109277

Keywords

Hybrid simulated annealing-genetic algorithm; Multi-area power system; Automatic generation control; PID controller; Governor dead band; Optimization

Ask authors/readers for more resources

In this study, a novel hybrid Simulated Annealing-Genetic Algorithm (hSA-GA) is proposed and tested on benchmark functions. It is then applied to tune PID parameters and optimize the control performance of automatic generation control (AGC) in power systems.
In this study, a novel hybrid Simulated Annealing-Genetic Algorithm (hSA-GA) is proposed. In the hSA-GA, population-based SA is used and each solution in the population is improved using the local search operator. The information exchange between the improved solutions is provided by the crossover operator. A new selection operator is used to ensure the balance between intensification and diversification. The hSA-GA is tested first on nine benchmark functions. Then it is used for tuning proportional-integral-derivative (PID) parameters for automatic generation control (AGC) of multi-area interconnected power systems. Firstly, PID parameters are determined with hSA-GA on a two-area interconnected non-reheating thermal system (System-1) in two different generator time constants. Secondly, to demonstrate the effect of supplementary control in AGC systems, the system is simulated with hSA-GA tuned PID controller and without controller. Additionally, the performance of the proposed hSA-GA is observed on AGC system of two area thermal power system with governor dead-band (GDB) nonlinearity (System-2). Transient responses of delta f(1), delta f(2) and delta P-tie obtained for both System-1 and System-2 are compared with studies on the same systems in the literature and it is seen that hSA-GA exhibits better control performance on power systems than compared studies. The proposed algorithm shows the best performance in System-1 (when T-g = 0.08). Accordingly, settling times of delta f(1), delta f(2) and delta P-tie are reduced to 2.33 s, 3.783 s and 3.11 s, respectively. Finally, the non-linear two area thermal power system is tested with a load varying between +/- 50% for 180 s to validation of proposed algorithm and results are compared relevant studies. (C) 2022 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available