4.8 Article

Rapid quantification of demand response potential of building HAVC system via data-driven model

Journal

APPLIED ENERGY
Volume 325, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2022.119796

Keywords

Demand response potential; Flexibility; Data-driven model; Modelica; Building energy systems

Funding

  1. China Postdoctoral Science Foundation [2021 M702447]

Ask authors/readers for more resources

This paper proposes a framework for rapidly quantifying the demand response potential of buildings and their energy systems. By utilizing detailed co-simulation and data-driven methods, the demand response potential of buildings under different meteorological conditions and control strategies can be accurately captured, and the framework is easy to apply in practice.
Buildings and heating, ventilation and air-conditioning systems are appropriate resources for demand response, but there is still a lack of rapid quantification methods to reveal buildings' dynamic demand response potential under different meteorological conditions and control strategies. In order to achieve real-time power grid dispatch and to facilitate grid-building interaction, this paper proposes a framework for establishing models to rapidly quantify the demand response potential of resources. First, a detailed co-simulation model of the building and its energy system is constructed, followed by extensive stochastic simulations of two commonly used demand response strategies, after which the demand response potential is quantified using a set of indices. Then, feature selection is performed on factors that may affect demand response potential, and a data-driven model for quantifying demand response potential is proposed, whose results are compared with those from the simulation model. Also, the demand response effects of the two control strategies are compared in this paper. A case study was carried out in an industrial building in Shenzhen, China. The results showed that under different boundaries, the coefficient of determination (R-2) of the quantification indices are all above 0.9, and that the data-driven model rapidly and accurately captured the demand response potential of the building and its heating, ventilation and air-conditioning system, and was easy to deploy in practice.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available