4.8 Article

Multiattribute Monitoring of Charge-Based Heterogeneity of Recombinant Monoclonal Antibodies Using 2D HIC-WCX-MS

Journal

ANALYTICAL CHEMISTRY
Volume 94, Issue 43, Pages 15018-15026

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.2c02931

Keywords

-

Funding

  1. Agilent Thought Leader award
  2. Department of Biotechnology, Ministry of Science and Technology [BT/COE/34/SP15097/2015]

Ask authors/readers for more resources

Charged heterogeneity of monoclonal antibody products is a critical quality attribute that requires comprehensive characterization to ensure product quality throughout its lifecycle. A novel two-dimensional liquid chromatography method coupled with mass spectrometry was used to identify more variants in mAb products compared to conventional methods, allowing for direct characterization of variant peaks.
Charged heterogeneity of monoclonal antibody (mAb) products is regarded as a critical quality attribute (CQA) depending on its impact on the safety and efficacy profile of the product. Hence, manufacturers are expected to perform a comprehensive characterization of the charge heterogeneity to ensure that the manufactured product meets its specifications. Further, monitoring is also expected during the product lifecycle to demonstrate consistency in product quality. However, conventional analytical methods for characterization of hydrophobic and charge variants are nonvolatile salt-based and require manual fraction collection and desalting steps before analysis through mass spectrometry can be performed. In the present study, a workflow of a two-dimensional liquid chromatography method using mass spectrometry (MS)-compatible buffers coupled with native mass spectrometry was performed to characterize hydrophobic variants in the first dimension and charge variants in the second dimension without any need for manual fractionation. This novel two-dimensional (2D) hydrophobic interaction chromatography (HIC)-weak cation-exchange chromatography (WCX)-MS workflow identified 10 variants in mAb A, out of which 2 variants are exclusive to the 2D orthogonal method. Similarly, for mAb B, a total of 11 variants are identified, including 5 variants exclusive to the 2D orthogonal workflow. When compared to stand-alone, HIC resolved only 4 variants for both mAbs and WCX resolved 7 variants for mAb A and 6 variants for mAb B. In addition, the proposed method allows direct characterization of hydrophobic/charge variant peaks through native mass spectrometry in a single-run workflow.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available