4.4 Article

The Role of Magnetic Resonance Imaging in the Planning of Surgical Treatment of Deep Pelvic Endometriosis

Journal

FRONTIERS IN SURGERY
Volume 9, Issue -, Pages -

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fsurg.2022.944399

Keywords

deep pelvic endometriosis; magnetic resonance imaging; diagnosis; surgical treatment; videolaparoscopic

Categories

Ask authors/readers for more resources

This study aimed to evaluate the diagnostic accuracy of MRI in the planning of surgical treatment for deep pelvic endometriosis. The results showed that MRI had high accuracy in detecting deep pelvic endometriosis in specific locations, allowing for the localization of lesions with highly fibrotic components. Compared to other imaging methods, MRI provides better visualization.
Background: To prospectively evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) for the planning of surgical treatment of deep pelvic endometriosis. Materials and Methods: From January 2020 to December 2021, we evaluated 72 patients with symptoms characteristic of endometriosis to plan appropriate surgical treatment. Sensitivity (Se), specificity (Sp), positive and negative predictive values (VPP/VPN), and the accuracy of MRI for the detection of deep pelvic endometriosis were calculated. Results: Seventy-two patients (mean age, 35.5 years; range, 20-46 years) suspected of having pelvic endometriosis were recruited. Pelvic endometriosis was confirmed at pathologic examination in 56 (77.7%) of 72 patients. A total of 22 (39.3%) of 56 patients were subjected to video laparoscopy (VLS), and 16 (72.2%) of 22 were treated by surgery. Se, Sp, VPP, and VPN in intestinal endometriosis diagnosis were, respectively, 100%, 93.3%, 100%, and 87.5%, and diagnostic accuracy was 95.4%. MRI Se in ureteral endometriosis diagnosis was 50%, Sp 100%, VPP 100%, VPN 78%, and diagnostic accuracy 82%. MRI Se in endometrioma diagnosis was 92.3%, Sp 100%, VPP 100%, VPN 90%, and diagnostic accuracy 95.4%. MRI Se in rectum-vaginal septum (SRV) endometriosis diagnosis was 80%, Sp 100%, VPP 100% VPN 85.7%, and diagnostic accuracy 91%. The MRI Se in the diagnosis of endometriosis involving ULS was 100%, Sp 92.8%, VPP 89%, VPN 100%, and diagnostic accuracy 95.4%. Complete concordance results in a 100% accuracy for all calculated values in diagnosing bladder endometriosis localizations. Conclusion: MR imaging demonstrates high accuracy in detecting deep pelvic endometriosis in specific locations. It allows the localization of deep pelvic lesions with highly fibrotic components that are hardly recognizable with other imaging methods and not visible with VLS.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available