4.7 Article

A Mouse Holder for Awake Functional Imaging in Unanesthetized Mice: Applications in 31P Spectroscopy, Manganese-Enhanced Magnetic Resonance Imaging Studies, and Resting-State Functional Magnetic Resonance Imaging

Journal

BIOSENSORS-BASEL
Volume 12, Issue 8, Pages -

Publisher

MDPI
DOI: 10.3390/bios12080616

Keywords

MRI; mouse; animal holder; awake; MEMRI; rs-fMRI; anesthesia

Funding

  1. [R01EB026453]
  2. [R56AG071152]

Ask authors/readers for more resources

This article introduces a newly designed mouse holder that allows for awake in vivo mouse imaging and demonstrates significant differences in P-31 spectra, MEMRI transport rates, and rs-fMRI connectivity between anesthetized and awake animals. This highlights the importance of using unanesthetized animals in functional studies.
Anesthesia is often used in preclinical imaging studies that incorporate mouse or rat models. However, multiple reports indicate that anesthesia has significant physiological impacts. Thus, there has been great interest in performing imaging studies in awake, unanesthetized animals to obtain accurate results without the confounding physiological effects of anesthesia. Here, we describe a newly designed mouse holder that is interfaceable with existing MRI systems and enables awake in vivo mouse imaging. This holder significantly reduces head movement of the awake animal compared to previously designed holders and allows for the acquisition of improved anatomical images. In addition to applications in anatomical T-2-weighted magnetic resonance imaging (MRI), we also describe applications in acquiring P-31 spectra, manganese-enhanced magnetic resonance imaging (MEMRI) transport rates and resting-state functional magnetic resonance imaging (rs-fMRI) in awake animals and describe a successful conditioning paradigm for awake imaging. These data demonstrate significant differences in P-31 spectra, MEMRI transport rates, and rs-fMRI connectivity between anesthetized and awake animals, emphasizing the importance of performing functional studies in unanesthetized animals. Furthermore, these studies demonstrate that the mouse holder presented here is easy to construct and use, compatible with standard Bruker systems for mouse imaging, and provides rigorous results in awake mice.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available