4.6 Article

Lower pulmonary vein-to-left atrium volume ratio predicts poor rhythm outcome after atrial fibrillation catheter ablation

Journal

FRONTIERS IN CARDIOVASCULAR MEDICINE
Volume 9, Issue -, Pages -

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fcvm.2022.934168

Keywords

atrial fibrillation; catheter ablation; pulmonary vein; left atrium; computed tomography

Ask authors/readers for more resources

This study found that left atrial (LA) size only affects 1-year recurrence rate after catheter ablation in the highest tertile group, while pulmonary vein (PV) to LA volume ratio (PV/LA%vol) can predict 1-year recurrence rate in all LA size groups. Patients with lower PV/LA%vol have a higher AF recurrence rate, and in patients with smaller LA size, PV/LA%vol is more accurate in predicting AF recurrence rate compared to LA dimension (LAD). Additionally, PV/LA%vol is associated with the PITX2 gene.
Although left atrial (LA) dimension (LAD) is one of the predictors of atrial fibrillation (AF) recurrence after catheter ablation, repetitive recurrences occur in patients without enlarged LAD. We explored the predictive value of pulmonary vein (PV) to LA volume percent ratio (PV/LA%vol) for rhythm outcomes after AF catheter ablation (AFCA). We included 2913 patients (73.5% male, 60.0 [52.0-67.0] years old, 60.6% paroxysmal AF) who underwent AFCA. We evaluated the association between PV/LA%vol and AF recurrence after AFCA and compared the predictive value for AF recurrences according to the LA size with LAD. We additionally investigated the association between PV/LA%vol and PITX2 gene using a genome-wide association study. LAD affected 1-year recurrence only in the highest tertile group (T3, p = 0.046), but PV/LA%vol determined 1-year recurrence in all LAD groups (T1, p = 0.044; T2, p = 0.021; and T3, p = 0.045). During 20.0 (8.0-45.0) months of follow-up, AF recurrence rate was significantly higher in patients with lower PV/LA%vol (Log-rank p = 0.004, HR 0.91 [0.84-1.00], p = 0.044). In the T1 and T2 LAD groups, predicting AF recurrences was better with PV/LA%vol than with LAD (AUC 0.63 vs. 0.51, p < 0.001 at T1; AUC 0.61 vs. 0.50, p = 0.007 at T2). We replicated PITX2-related rs12646447, which was independently associated with PV/LA%vol (beta = 0.15 [0-0.30], p = 0.047). In conclusion, smaller PV volumes after LA volume adjustments have genetic background of PITX2 gene and predictive value for poorer rhythm outcomes after AFCA, especially in patients without LA enlargement.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available