4.7 Article

Application and CFD-Based Optimization of a Novel Porous Object for Confined Slot Jet Impingement Cooling Systems under a Magnetic Field

Journal

MATHEMATICS
Volume 10, Issue 15, Pages -

Publisher

MDPI
DOI: 10.3390/math10152578

Keywords

jet impingement; optimization; MHD; hybrid nanofluid; finite element method; COBYLA

Categories

Funding

  1. Scientific Research Deanship at University of Ha'il-Saudi Arabia [RG-21 057]

Ask authors/readers for more resources

A novel porous object is introduced in this study for the control of convective heat transfer in confined slot nanojet impingement under magnetic field effects. Optimization-assisted computational fluid dynamics is used to find the best working conditions to achieve optimal performance. The flow, thermal patterns, and heat transfer characteristics are influenced by the variation in rotational Reynolds number, Hartmann number, permeability of the porous object, and its location.
A novel porous object for the control of the convective heat transfer of confined slot nanojet impingement is offered under magnetic field effects, while optimization-assisted computational fluid dynamics is used to find the best working conditions to achieve the best performance of the system. The flow, thermal patterns, and heat transfer characteristics were influenced by the variation in rotational Reynolds number (Rew), Hartmann number (Ha), permeability of the porous object (Da) and its location (Mx). There was a 14.5% difference in the average Nusselt number (Nu) at the highest Rew when motionless object configuration at Ha = 5 was compared, while it was less than 2% at Ha = 25. At Rew = -600, the average Nu variation was 22% when cases with the lowest and highest magnetic field strength were compared. The porous object provides an excellent tool for convective heat transfer control, while the best performance was achieved by using optimization-assisted computational fluid dynamics. The optimal sets of (Rew, Da, Mx, AR) for porous object were (-315.97, 0.0188, -1.456, 0.235), (-181.167, 0.0167, -1.441, 0.2), and (-483.13, 0.0210, -0.348, 0.2) at Ha = 5, 10, and 25, respectively. At the optimal operating point, the local Nu enhancements were 19.46%, 44.86%, and -0.54% at Ha = 5, 10, and 15, respectively, when the no-object case was compared, while the average values were 7.87%, 8.09% and 5.04%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available