4.6 Article

Virtual Monochromatic Images from Dual-Energy Computed Tomography Do Not Improve the Detection of Synovitis in Hand Arthritis

Journal

DIAGNOSTICS
Volume 12, Issue 8, Pages -

Publisher

MDPI
DOI: 10.3390/diagnostics12081891

Keywords

dual-energy CT; ultrasound; virtual monochromatic imaging; arthritis; rheumatoid; synovitis

Ask authors/readers for more resources

The study aimed to compare subtraction images from different polychromatic and virtual monochromatic reconstructions for the detection of inflammation in patients with hand arthritis. The results showed that the 70 KeV images had the highest diagnostic accuracy and sensitivity, while the 50 KeV images had the lowest image quality. Virtual monochromatic reconstructions did not show significant improvement in detecting inflammation compared to conventional subtraction techniques.
The objective of this study was to investigate subtraction images from different polychromatic and virtual monochromatic reconstructions of dual-energy computed tomography (CT) for the detection of inflammation (synovitis/tenosynovitis or peritendonitis) in patients with hand arthritis. In this IRB-approved prospective study, 35 patients with acute hand arthritis underwent contrast-enhanced dual-energy CT and musculoskeletal ultrasound (MSUS) of the clinically dominant hand. CT subtractions (CT-S) were calculated from 80 and 135 kVp source data and monochromatic 50 and 70 keV images. CT-S and MSUS were scored for synovitis and tenosynovitis/peritendonitis. Specificity, sensitivity and diagnostic accuracy were assessed by using MSUS as a reference. Parameters of objective image quality were measured. Thirty-three patients were analyzed. MSUS was positive for synovitis and/or tenosynovitis/peritendonitis in 28 patients. The 70 keV images had the highest diagnostic accuracy, with 88% (vs. 50 keV, 82%; 80 kVp, 85%; and 135 kVp, 82%), and superior sensitivity, with 96% (vs. 50 keV: 86%, 80 kVp: 93% and 135 kVp: 79%). The 80 kVp images showed the highest signal- and contrast-to-noise ratio, while the 50 keV images provided the lowest image quality. While all subtraction methods of contrast-enhanced dual-energy CT proved to be able to detect inflammation with sufficient diagnostic accuracy, virtual monochromatic images with low keV showed no significant improvement over conventional subtraction techniques and lead to a loss of image quality.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available