4.6 Article

Deep Learning Models for Segmenting Non-perfusion Area of Color Fundus Photographs in Patients With Branch Retinal Vein Occlusion

Journal

FRONTIERS IN MEDICINE
Volume 9, Issue -, Pages -

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fmed.2022.794045

Keywords

deep learning; non-perfusion area; color fundus photograph; branch retinal vein occlusion; artificial intelligence; automatic segmentation

Ask authors/readers for more resources

DL models developed with AI-based deep learning can accurately detect ischemia type and non-perfusion areas from color fundus photographs of patients with BRVO.
PurposeTo develop artificial intelligence (AI)-based deep learning (DL) models for automatically detecting the ischemia type and the non-perfusion area (NPA) from color fundus photographs (CFPs) of patients with branch retinal vein occlusion (BRVO). MethodsThis was a retrospective analysis of 274 CFPs from patients diagnosed with BRVO. All DL models were trained using a deep convolutional neural network (CNN) based on 45 degree CFPs covering the fovea and the optic disk. We first trained a DL algorithm to identify BRVO patients with or without the necessity of retinal photocoagulation from 219 CFPs and validated the algorithm on 55 CFPs. Next, we trained another DL algorithm to segment NPA from 104 CFPs and validated it on 29 CFPs, in which the NPA was manually delineated by 3 experienced ophthalmologists according to fundus fluorescein angiography. Both DL models have been cross-validated 5-fold. The recall, precision, accuracy, and area under the curve (AUC) were used to evaluate the DL models in comparison with three types of independent ophthalmologists of different seniority. ResultsIn the first DL model, the recall, precision, accuracy, and area under the curve (AUC) were 0.75 +/- 0.08, 0.80 +/- 0.07, 0.79 +/- 0.02, and 0.82 +/- 0.03, respectively, for predicting the necessity of laser photocoagulation for BRVO CFPs. The second DL model was able to segment NPA in CFPs of BRVO with an AUC of 0.96 +/- 0.02. The recall, precision, and accuracy for segmenting NPA was 0.74 +/- 0.05, 0.87 +/- 0.02, and 0.89 +/- 0.02, respectively. The performance of the second DL model was nearly comparable with the senior doctors and significantly better than the residents. ConclusionThese results indicate that the DL models can directly identify and segment retinal NPA from the CFPs of patients with BRVO, which can further guide laser photocoagulation. Further research is needed to identify NPA of the peripheral retina in BRVO, or other diseases, such as diabetic retinopathy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available