4.6 Article

External Support for Saphenous Vein Grafts in Coronary Artery Bypass Surgery A Randomized Clinical Trial

Journal

JAMA CARDIOLOGY
Volume 7, Issue 8, Pages 808-816

Publisher

AMER MEDICAL ASSOC
DOI: 10.1001/jamacardio.2022.1437

Keywords

-

Funding

  1. Vascular Graft Solutions Ltd (Tel Aviv, Israel)

Ask authors/readers for more resources

In this study, the impact of external vein graft support devices on intimal hyperplasia did not reach statistical significance, but the overall mortality and major cardiac or cerebrovascular event rates were similar to other coronary artery bypass trials. Further investigation is needed to assess the effect of external support devices on long-term graft patency and clinical outcomes.
IMPORTANCE Intimal hyperplasia and subsequent saphenous vein graft failure may have significant adverse clinical effects in patients undergoing coronary artery bypass surgery. External support of saphenous vein grafts has the potential to prevent vein graft dilation and hence slow the rate of intimal hyperplasia and increase long-term vein patency. OBJECTIVE To determine efficacy, as measured by intimal hyperplasia, and safety of an external saphenous vein graft support device in patients undergoing a coronary bypass graft procedure. DESIGN, SETTING, AND PARTICIPANTS This within-patient randomized, open-label, multicenter study was conducted at 17 Cardiothoracic Surgical Trials Network centers in North America. Between January 2018 and February 2019, 224 patients with multi vessel coronary artery disease undergoing isolated bypass surgery were enrolled. For each patient, 1 of 2 vein grafts was randomized to receive external support or no support. INTERVENTIONS External vein graft support or no support. MAIN OUTCOMES AND MEASURES The primary efficacy end point was intimal hyperplasia area assessed by intravascular ultrasound at 12 months postrandomization for each study graft. Secondary confirmatory end points were lumen diameter uniformity assessed by angiography and graft failure (>= 50% stenosis) by quantitative coronary angiography. Major cardiac and cerebrovascular events were collected through month 12. RESULTS Among 224 patients (mean [SD] age, 65.8 [8.3] years; 178 [79.5%) male), 203 (90.6%) were eligible for intravascular ultrasound, of which 85 (41.9%) had at least 1 study graft occluded or severely diseased at 12 months (55 supported, 56 unsupported). After imputation of data missing because of graft occlusion or severe disease, the estimated mean (SE) intimal hyperplasia area was 5.11(0.16) mm(2) in supported grafts and 5.79 (0.20) mm(2) in unsupported grafts (P = .07). In a sensitivity analysis of 113 patients with both grafts imaged, the mean intimal hyperplasia area was 4.58 (0.18) mm(2) and 5.12 (0.23) mm(2) in supported and unsupported grafts, respectively (P = .04). By 12 months, 5 patients (2.2%) died and 16 patients (7.1%) experienced a major cardiac or cerebrovascular event. CONCLUSIONS AND RELEVANCE The 12-month difference in intimal hyperplasia area between supported and unsupported grafts did not achieve statistical significance. Cumulative mortality and major cardiac or cerebrovascular events rates were similar to those in other randomized coronary artery bypass trials. Further investigation to assess the effect of external graft support devices on long-term graft patency and clinical outcomes is warranted.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available