Wear Analysis of Four Different Single-File Reciprocating Instruments before and after Four Uses in Simulated Root Canals

Journal

APPLIED SCIENCES-BASEL
Volume 12, Issue 12, Pages -

Publisher

MDPI
DOI: 10.3390/app12126253

Keywords

endodontics; nickel-titanium rotary instruments; reciprocation; root canal treatment; scanning electron microscopy; wear analysis

Ask authors/readers for more resources

This study assessed surface alterations of four reciprocating instruments before and after shaping resin-simulated root canals, showing significant differences in cutting edges for one instrument and higher presence of debris for another after simulated use.
The aim of this study is to assess the surface alterations of four reciprocating instruments before and after the shaping of four resin-simulated root canals. The following four different reciprocating instruments are selected: 10 Reciproc Blue (RB25), 10 WaveOne Gold (WOG), 10 EdgeOne Fire (EOF) and 10 recently introduced instruments OneRECI (OR), for a total of 40 new instruments. Before root canal shaping, each instrument is mounted on a stub in a standardized position and observed using a scanning electron microscope (SEM) to detect any surface alteration, such as microfractures, metal defects, deformations, blunt and disruption of cutting edges, debris, pitting and tip flattening. Micrographs are acquired at the level of the tip, 4 mm, 8 mm and 12 mm from it. After that, each instrument is used in four simulated resin root canals. SEM observation was repeated after the simulated clinical use to assess the wear resistance of the instruments. Surface alterations are registered before and after instrumentation and statistical analysis is performed using a Chi-Square test to verify homogeneity of defects distribution and GLM to evaluate the differences of RMS at baseline and after use for both groups (alpha level 0.05). Before simulated clinical uses, no alterations are found except for three cases of EOF with metal strips in correspondence to the tip, disruption of the cutting edge of WOG and oily spotting on two different OR. After simulated clinical use, EOF shows a statistically significant difference in terms of spiral distortion and flattening of the cutting edges. The OR shows the highest presence of debris despite the ultrasonic cleaning procedures. No instrument fractures are observed. EOF should be discarded after four clinical uses and carefully inspected after each insertion into root canals. Moreover, tough attention should be paid during disinfection and cleaning procedures after instrumentation considering the copious debris detected in each instrument, particularly in OR.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available