Insufficient service life and the need for battery replacements are major challenges for implantable electronic devices. To address this issue, researchers have developed a biomechanical energy harvester that uses animals' body bending movements to power implantable and wearable devices. Experiments using fish as test subjects have shown successful signal transmissions for up to 5 weeks, but the limited lifespan of the energy harvester remains a constraint.
Insufficient service life and the resulting need for battery replacements have been a great challenge for implantable electronic devices. This is particularly true for animal tracking applications, because recapturing animals is often unlikely once they are released to the wild. To tackle this problem, we developed a biomechanical energy harvester that uses a Macro Fiber CompositeTM (MFC) piezoelectric beam to harvest the mechanical energy from animals' body bending movements as the power source for implantable and wearable devices. Prototypes of an underwater acoustic transmitter using this technology were subdermally implanted into juvenile white sturgeon and their energy harvesting performance was evaluated through the devices' transmissions. The fish successfully recovered from the implantation surgery and freely swam inside a tank. The transmitter prototypes in the fish continually transmitted signals for a period up to 5 weeks. A benchtop test setup was also created to emulate the fish's body bending, estimate the device's energy harvesting performance in the live fish, and perform accelerated fatigue testing of the energy harvester by applying test parameters learned from a video study of the fish's body movement and behavior characteristics. The gradual depolarization of the piezoelectric ceramic material in the MFC under cyclic mechanical loading was the main limiting factor for the life span of the energy harvester. Pathways for improvement are proposed to achieve long-term efficacy of powering implantable and wearable electronic devices.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available