4.3 Article

Correlation of component human body model and charged device model qualification levels with electrical failures in electronics assembly

Journal

JOURNAL OF ELECTROSTATICS
Volume 79, Issue -, Pages 38-44

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.elstat.2015.12.002

Keywords

ESD; HBM; CDM; Electrical failures; Assembly

Ask authors/readers for more resources

Electrostatic discharge sensitivity of integrated circuits is compared with electrical failure levels in electronics assembly. Electrical components with a low electrostatic discharge withstand voltage would be expected to have more electrical failures than more robust components. However, the analysis based on 47 products, 14 facilities, and 6 billion integrated circuits show no correlation between electrical failures and electrostatic discharge sensitivity of components. This was found when the withstand voltage of the components is equal or higher than 100 V human body model and 200 V charged device model. (c) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available