4.5 Article

Racial bias and reproducibility in pulse oximetry among medical and surgical inpatients in general care in the Veterans Health Administration 2013-19: multicenter, retrospective cohort study

Journal

BMJ-BRITISH MEDICAL JOURNAL
Volume 378, Issue -, Pages -

Publisher

BMJ PUBLISHING GROUP
DOI: 10.1136/bmj-2021-069775

Keywords

-

Funding

  1. NIH [5T32HS000053-29, R01-HS026725]
  2. VA HSRD [R01 HL158626]
  3. VA [IIR 17-045]
  4. AHRQ [IIR 17-2019]
  5. NHLBI [K23140165]
  6. National Clinician Scholars Program

Ask authors/readers for more resources

This study aimed to evaluate measurement discrepancies between pulse oximetry and arterial oxygen saturation among inpatients in general care settings. The results showed that black patients were more likely to have occult hypoxemia noted on arterial blood gas but not detected by pulse oximetry compared to white patients.
OBJECTIVES To evaluate measurement discrepancies by race between pulse oximetry and arterial oxygen saturation (as measured in arterial blood gas) among inpatients not in intensive care. DESIGN Multicenter, retrospective cohort study using electronic medical records from general care medical and surgical inpatients. SETTING Veteran Health Administration, a national and racially diverse integrated health system in the United States, from 2013 to 2019. PARTICIPANTS Adult inpatients in general care (medical and surgical), in Veteran Health Administration medical centers. MAIN OUTCOMES MEASURES Occult hypoxemia (defined as arterial blood oxygen saturation (SaO2) of < 88% despite a pulse oximetry (SpO2) reading of a92%), and whether rates of occult hypoxemia varied by race and ethnic origin. RESULTS A total of 30 039 pairs of SpO2-SaO2 readings made within 10 minutes of each other were identified during the study. These pairs were predominantly among non-Hispanic white (21 918 (73.0%)) patients; non-Hispanic black patients and Hispanic or Latino patients accounted for 6498 (21.6%) and 1623 (5.4%) pairs in the sample, respectively. Among SpO2 values greater or equal to 92%, unadjusted probabilities of occult hypoxemia were 15.6% (95% confidence interval 15.0% to 16.1%) in white patients, 19.6% (18.6% to 20.6%) in black patients (P < 0.001 v white patients, with similar P values in adjusted models), and 16.2% (14.4% to 18.1%) in Hispanic or Latino patients (P=0.53 v white patients, P < 0.05 in adjusted models). This result was consistent in SpO2-SaO2 pairs restricted to occur within 5 minutes and 2 minutes. In white patients, an initial SpO2-SaO2 pair with little difference in saturation was associated with a 2.7% (95% confidence interval-0.1% to 5.5%) probability of SaO2 < 88% on a later paired SpO2-SaO2 reading showing an SpO2 of 92%, but black patients had a higher probability (12.9% (-3.3% to 29.0%)). CONCLUSIONS In general care inpatient settings across the Veterans Health Administration where paired readings of arterial blood gas (SaO2) and pulse oximetry (SpO2) were obtained, black patients had higher odds than white patients of having occult hypoxemia noted on arterial blood gas but not detected by pulse oximetry. This difference could limit access to supplemental oxygen and other more intensive support and treatments for black patients.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available