4.7 Article

Mesopic conditions optimise the detection of visual function loss in drivers with simulated media opacity

Journal

SCIENTIFIC REPORTS
Volume 12, Issue 1, Pages -

Publisher

NATURE PORTFOLIO
DOI: 10.1038/s41598-022-17448-w

Keywords

-

Funding

  1. Ulster University
  2. Department of Health through National Institute for Health Care Research
  3. University College London Institute of Ophthalmology

Ask authors/readers for more resources

This study investigated the sensitivity of photopic and mesopic conditions to detect contrast sensitivity (CS) loss in drivers with simulated media opacities. The results showed that mesopic conditions were more vulnerable to different levels of simulated media opacity. This suggests that mesopic conditions should be considered when assessing visual function in older drivers at risk of media opacity.
Drivers have different visual demands across varying contrast and luminance conditions. However, vision assessments for driving are typically conducted under photopic conditions. This study investigated the sensitivity of photopic and mesopic conditions to detect contrast sensitivity (CS) loss in drivers with simulated media opacities. CS was measured in forty-seven healthy drivers aged 18-50 years (mean +/- SD: 25.5 +/- 6.5) under photopic and mesopic-adapted luminance levels with the Pelli-Robson chart and the Mesotest II (without glare). Media opacities were simulated using white-opacity containing Lee Fog filters (1-5) and CS measured in a randomised order. A significant (p < 0.001) reduction in photopic CS (logCS) was measured with the Pelli-Robson chart only when media opacity was simulated with Fog filter 5 (1.53 +/- 0.15, 2.8 triplets reduction) compared to baseline (1.95 +/- 0.03). Mean mesopic CS demonstrated a significant (all p < 0.001) reduction from baseline (1.67 +/- 0.14) for Fog filters 3 (1.4 triplets, 1.45 +/- 0.16), 4 (2.4 triplets, 1.31 +/- 0.14) and 5 (4.3 triplets, 1.02 +/- 0.15). For Mesotest II, only Fog filter 5 produced a significant reduction (0.10 +/- 0.09; p < 0.001) in mean mesopic CS from baseline (0.30 +/- 0.01). Mesopic CS is more vulnerable to different levels of simulated media opacity, hence should be considered clinically when assessing visual function in older drivers at risk of media opacity.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available