4.7 Article

Amperometric sensor based on multi-walled carbon nanotube and poly (Bromocresol purple) modified carbon paste electrode for the sensitive determination of L-tyrosine in food and biological samples

Journal

JOURNAL OF ELECTROANALYTICAL CHEMISTRY
Volume 778, Issue -, Pages 32-40

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.jelechem.2016.08.010

Keywords

Tyrosine; Modified carbon paste electrode; Electro-polymerization; Bromocresol purple; Multi-walled carbon nanotube; Amperometry

Funding

  1. Board of Research in Nuclear Sciences (BRNS, BARC, Mumbai), Department of Atomic Energy, Government of India [37(2)/14/10/2014-brns]

Ask authors/readers for more resources

An amperometric sensor was developed based on multi-walled carbon nanotubes and poly (Bromocresol purple) modified carbon paste electrode, for the sensitive investigation of L-Tyrosine (Tyr). The surface morphology of the electrodes was studied using field emission scanning electron microscopy (FE-SEM), atomic force microscopy (AFM) while electron impedance spectroscopy (EIS) was employed to throw light on electrode - electrolyte interface properties. The symbiotic effect of the bulk modification and electro-polymerization was evident by 5.5 times increase in the peak current compared to the bare carbon paste electrode (CPE). Cyclic voltammetry (CV) technique was used for the qualitative analysis of Tyr at the modified electrode. The amperometric results showed that the anodic current was proportional to the Tyr concentration in ranges of 2.0 mu M-100.0 mu M with a. lower detection limit of (1.91 +/- 0.27) x 10(-7) M (signal/noise = 3) at physiological pH. The CV and amperometric response of Tyr was examined in the presence of co-existing bio-molecules and the results indicated that the electrode had good anti-interference ability and could be subjected easily to real sample analysis. The low cost, high sensitivity, stability, reproducibility and anti-interference ability of the sensor offer an avenue to broaden its applications. The sensor was also tested for its practical applications by spiking Tyr in milk and blood serum samples and the recoveries obtained were found to be satisfactory. (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available