4.3 Article

Diagnostic accuracy of digital Brix and serum total protein refractometers in estimating different passive immunity levels in dairy calves

Journal

VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY
Volume 249, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.vetimm.2022.110442

Keywords

Brix refractometer; Calf; IgG; Transfer of passive immunity; Serum total protein

Funding

  1. General Directorate of Agricultural Enterprises (Tarim Isletmeleri Genel Mudurlugu, TIGEM)

Ask authors/readers for more resources

The study determined the diagnostic accuracy of digital Brix and digital serum TP refractometers in estimating passive immunity levels in dairy calves, showing moderate to high accuracy. The refractometers agreed with each other and were in substantial agreement with RID-IgG results, indicating their utility in determining passive immunity levels in dairy calves.
The aim of this study was to determine the diagnostic accuracy of digital serum total protein (TP) and digital Brix refractometers in estimating different passive immunity levels (<10, <18, <25 mg/mL) in dairy calves. Blood samples were collected from 260 apparently healthy Holstein calves, aged 2-7 days. Serum IgG concentrations were measured using digital Brix and TP refractometers and the radial immunodiffusion (RID) assay, as the gold standard. Data were analyzed by a receiver operating characteristics (ROC) analysis, the area under the ROC curves (AUC) and Cohen's kappa (kappa). Optimal thresholds were determined as < 8.4, < 9.0 and < 9.4% for the digital Brix refractometer, and < 5.0, < 5.4 and < 5.8 g/dL for the serum TP refractometer in estimating IgG concentrations of < 10, < 18, < 25 mg/mL, respectively. The sensitivity (Se) and specificity (Sp) of the Brix refractometer were 96.3% and 88.8% for < 8.4% Brix, 97.0% and 83.4% for < 9.0% Brix, and 85.5% and 77.8% for < 9.4% Brix, respectively. The Se and Sp of the serum TP refractometer were 96.3% and 90.1% for < 5.0 g/ dL, 91.0% and 89.6% for < 5.4 g/dL, 79.6% and 85.2% for < 5.8 g/dL, respectively. The discriminant ability of the refractometers was moderately accurate in estimating IgG concentrations of < 10 and < 18 mg/mL, and highly accurate in estimating IgG concentrations of < 25 mg/mL. Both refractometers substantially agreed with RID-IgG results and almost perfectly agreed with each other. In conclusion, the digital Brix and digital serum TP refractometers offer a good utility for determining different passive immunity levels in dairy calves.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available