4.7 Article

Temperature variation inside a corridor-like enclosure under limited ventilation

Related references

Note: Only part of the references are listed.
Article Construction & Building Technology

Effect of single-side centralized exhaust on smoke control and temperature distribution in longitudinal ventilation tunnel fires

Liangliang Tao et al.

Summary: This study investigated smoke exhaust control and temperature distribution in a small-scale single-side centralized exhaust tunnel, finding that by controlling the appropriate smoke exhaust volume and longitudinal speed, smoke distribution in the tunnel can be effectively controlled, with temperature decay following an exponential attenuation law. A smoke control scheme and temperature decay calculation model for a ceiling point exhaust tunnel with one fan room were proposed based on the experimental results, with an error of less than 20% between the results and the prediction model.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2022)

Article Thermodynamics

Temperature evolution from stratified- to well-mixed condition inside a fire compartment with an opening subjected to external wind

Fei Ren et al.

Summary: It is well known that compartment fires evolve from stratified to well-mixed conditions as the heat release rate increases. However, the evolution of a compartment fire with an opening subjected to external wind has not been quantified, despite its practical significance. This study experimentally investigated the evolution of temperature spatial non-uniformness inside a fire compartment with varying opening dimensions, heat release rates, and wind speeds. The findings show that the temperature difference between the upper and lower part of the compartment initially increases then decreases with increasing heat release rate, and decreases with increasing wind speed.

PROCEEDINGS OF THE COMBUSTION INSTITUTE (2021)

Article Engineering, Civil

Experimental study of back-layering length and critical velocity in longitudinally ventilated tunnel fire with various rectangular cross-sections

Tianhang Zhang et al.

Summary: This study investigated the effects of tunnel aspect ratios on smoke back flow in longitudinally ventilated tunnel fires through scale model tests and theoretical analyses. The increase of tunnel width was found to enhance heat transfer and reduce smoke layer thickness, leading to decreased back-layering length and critical velocity. New correlations were proposed to predict these parameters with improved physical significance, showing good agreement with experimental data. Additionally, it was observed that non-dimensional critical velocity decreases with increasing aspect ratio under small fire conditions, ultimately approaching a limiting value. The determination of fire scale depends on aspect ratio when non-dimensional heat release rate is lower than 0.44, suggesting a relationship between tunnel geometry and fire size.

FIRE SAFETY JOURNAL (2021)

Article Engineering, Multidisciplinary

Investigation on the Tunnel Curvature Effect upon the Ceiling Temperature of Tunnel Fires: A Numerical Simulation

Kaihua Lu et al.

Summary: This study investigates the temperature distribution in curved tunnels through numerical simulation method, showing slightly different temperature distributions under different curvature radius conditions. A new exponential decay model is proposed for predicting the longitudinal temperature in tunnels with various curvature conditions.

FIRE TECHNOLOGY (2021)

Article Construction & Building Technology

Numerical simulation on the maximum temperature and smoke back-layering length in a tilted tunnel under natural ventilation

Xiaolei Zhang et al.

Summary: This study investigated the effects of fire on smoke flow in a tilted tunnel under natural ventilation through numerical simulations. Results showed that tunnel slope, fire source heat release rate, source-ceiling height, and tunnel width significantly affected the maximum temperature and smoke back-layering length.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2021)

Article Construction & Building Technology

Full-scale tests on smoke temperature distribution in long-large subway tunnels with longitudinal mechanical ventilation

Congling Shi et al.

Summary: This paper studies the fire behaviors of long-large subway tunnel and proposes a method to compute smoke temperature rise distribution, which can predict the distribution with a relative error within 20% based on full-scale tests. The results show that the proposed method has better correlation with the test data.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2021)

Article Construction & Building Technology

Experimental study on temperature profile in long-narrow compartment fire with multiple lateral openings

Min Peng et al.

Summary: Experimental results show that the lateral opening conditions mainly affect the temperature near the fire source in a long-narrow compartment, and this effect does not follow a single pattern with the change of the number of lateral openings. It is recommended to keep the openings near the fire source closed and symmetrically open the openings away from the fire source in the design process.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2021)

Article Construction & Building Technology

Effect of the blockage ratio on the smoke extraction efficiency in tunnel fires with natural ventilation

Jie Wang et al.

Summary: The study found that vehicle blockage can affect the smoke extraction efficiency of tunnel shafts, with the efficiency decreasing first, then increasing, and finally dropping with the increasing blockage ratio. The main influencing factors include blocking effect, necking effect, and stack effect of the shaft. The smoke extraction efficiency reaches the maximum around a blockage ratio of 0.48, providing a reference for engineering applications.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2021)

Article Energy & Fuels

Experimental study of flame extinction with fuel diffusion combustion inside a wall-opening compartment under reduced ventilation conditions

Xiepeng Sun et al.

Summary: This experimental study investigates the transient flame extinction behavior with fuel diffusion combustion inside a wall-opening compartment under reduced ventilation conditions. The researchers found that flame extinction is more likely to occur in smaller opening sizes or relatively larger compartment scales, and the time to reach flame extinction is influenced by fuel supply flow rate and opening size. Additionally, a formula was established to describe the critical gas temperature right before extinction as a function of a newly defined non-dimensional integrated parameter.
Article Thermodynamics

Temperature evolution and external flame height through the opening of fire compartment: Scale effect on heat/mass transfer and revisited models

Xiepeng Sun et al.

Summary: This paper investigates the temperature evolution inside a compartment and the external flame height ejected through the opening, revealing a scale effect on the problem and proposing models for predicting the upper-part temperature evolution. The external flame height shows significant differences for various compartment scales, leading to the proposal of a general model characterizing the external flame height with a newly defined dimensionless excess heat release rate.

INTERNATIONAL JOURNAL OF THERMAL SCIENCES (2021)

Article Construction & Building Technology

Study on temperature decay characteristics of fire smoke backflow layer in tunnels with wide-shallow cross-section

Tianhang Zhang et al.

Summary: The study found that tunnel aspect ratio significantly influences the smoke temperature decay rate, with a higher aspect ratio leading to faster smoke temperature decay due to increased contact area between the smoke layer and ceiling. Additionally, increasing fire heat release rate reduces the smoke temperature decay rate, while longitudinal ventilation velocity increases the longitudinal temperature decay rate and decreases the transverse temperature decay rate. A new model considering the effects of aspect ratio, longitudinal ventilation velocity and fire heat release rate shows good applicability in full-scaled tunnel testing conditions.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2021)

Article Construction & Building Technology

Maximum temperature of ceiling jet flow in longitudinal ventilated tunnel fires with various distances between fire source and cross-passage

Yunsong Li et al.

Summary: This study conducted numerical simulations on the maximum temperature rise of ceiling jet flow in tunnel fires under longitudinal ventilation with various distances between fire source and cross-passage. Results show that the maximum temperature rise decreases with increasing longitudinal ventilation velocity or decreasing heat release rate. The cross-passage affects the fire plume flow velocity under the ceiling, further affecting the maximum temperature.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2021)

Article Engineering, Multidisciplinary

Experimental Study on Fire Plume Characteristics in a Subway Carriage with Doors

Min Peng et al.

FIRE TECHNOLOGY (2020)

Article Construction & Building Technology

Effect of train fire location on maximum smoke temperature beneath the subway tunnel ceiling

Wei Cong et al.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2020)

Article Construction & Building Technology

Metro train carriage combustion behaviors - Full-scale experiment study

Congling Shi et al.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2020)

Article Construction & Building Technology

Effect of blockage on critical ventilation velocity in longitudinally ventilated tunnel fires

Na Meng et al.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2020)

Article Construction & Building Technology

Heat release rate of high-speed train fire in railway tunnels

Yuanlong Zhou et al.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2020)

Article Construction & Building Technology

Scale modeling study on flame colour in a ventilation-limited train car pool fire

Y. W. Ng et al.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2019)

Article Thermodynamics

Temperature profile of thermal flow underneath an inclined ceiling induced by a wall-attached fire

Xiaolei Zhang et al.

INTERNATIONAL JOURNAL OF THERMAL SCIENCES (2019)

Article Engineering, Environmental

A modified thermal radiation model with multiple factors for investigating temperature rise around pool fire

Congling Shi et al.

JOURNAL OF HAZARDOUS MATERIALS (2019)

Article Thermodynamics

A study on window plume from a room fire to the cavity of a double-skin facade

Lei Miao et al.

APPLIED THERMAL ENGINEERING (2018)

Article Thermodynamics

Effect of blockage-induced near wake flow on fire properties in a longitudinally ventilated tunnel

Na Meng et al.

INTERNATIONAL JOURNAL OF THERMAL SCIENCES (2018)

Article Engineering, Civil

Fire development in a 1/3 train carriage mock-up

Anders Lonnermark et al.

FIRE SAFETY JOURNAL (2017)

Article Materials Science, Multidisciplinary

Full-scale burning tests on double-skin facade fires

C. L. Chow

FIRE AND MATERIALS (2013)

Article Engineering, Civil

A model experimental study on backdraught in tunnel fires

J. Mao et al.

FIRE SAFETY JOURNAL (2011)

Article Engineering, Civil

The maximum temperature of buoyancy-driven smoke flow beneath the ceiling in tunnel fires

Ying Zhen Li et al.

FIRE SAFETY JOURNAL (2011)

Article Engineering, Civil

A new correlation for gas temperature inside a burning enclosure

Michael A. Delichatsios et al.

FIRE SAFETY JOURNAL (2009)

Article Engineering, Civil

Modeling thermal behaviors of window flame ejected from a fire compartment

Keisuke Himoto et al.

FIRE SAFETY JOURNAL (2009)

Article Engineering, Civil

Model scale railcar fire tests

Haukur Ingason

FIRE SAFETY JOURNAL (2007)

Article Thermodynamics

Heat fluxes and flame heights in facades from fires in enclosures of varying geometry

Yee-Ping Lee et al.

PROCEEDINGS OF THE COMBUSTION INSTITUTE (2007)

Article Construction & Building Technology

Full-scale burning tests on studying smoke temperature and velocity along a corridor

LH Hu et al.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2005)