4.7 Article

Highly sensitive few-layer MoS2 nanosheets as a stable soil moisture and humidity sensor

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 365, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2022.131930

Keywords

Microsensor; Humidity sensor; Soil moisture sensor; Liquid phase exfoliation; MoS2 nanosheets; Agriculture

Funding

  1. Ministry of Human Resource and Devel-opment (MHRD) , India

Ask authors/readers for more resources

In this study, an ultrasensitive humidity and soil moisture sensor based on MoS2 nanosheets was developed. The sensor showed a significant change in capacitance with varying relative humidity levels and soil moisture content. It exhibited fast response, long-term stability, and high accuracy.
In this work, an MoS2 nanosheet based ultrasensitive humidity and soil moisture sensor has been developed. MoS2 nanosheets are obtained by sonication based surfactant-induced exfoliation. The performance of the sensor is examined at room temperature (25 ?) with respect to various relative humidity (RH) levels and soil water content (theta g). A 434 fold variation (35-15200 pF) in capacitance value is seen when the relative humidity level changes from 11% to 96%. The response and recovery times of the microsensor are approximately 30 s and 40 s, respectively. The capacitance of the MoS2 based sensor increases monotonically when the soil moisture content increases from 3.6% to 53% and 2.3-45% for black and red soil, respectively. The observed variation in capacitance corresponding to theta gB = 53% (black soil moisture content) and theta(gR) = 45% (red soil moisture content) is approximately 250 and 200 times that observed for the respective dry soil samples. The error in the soil moisture response measurement for the temperature variation from 25 ? to 70 ? is +/- 2.52%. The device features stable performance for six months with reasonably high accuracy (maximum error & PLUSMN; 1.50%). The soil sensing results show fast response (35 s), negligible hysteresis error (2.80% at theta(gB) = 31.9%), long-term stability (6 months and more), and good reproducibility (with more than 10 cycles).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available