4.6 Article

Development of a Non-Contacting Muscular Activity Measurement System for Evaluating Knee Extensors Training in Real-Time

Journal

SENSORS
Volume 22, Issue 12, Pages -

Publisher

MDPI
DOI: 10.3390/s22124632

Keywords

muscular activity estimation; knee extensors; muscle training; rehabilitation; real-time; neuron network; IMU sensor

Funding

  1. China Scholarship Council (CSC) [[2018]3101]

Ask authors/readers for more resources

To provide people with more specific information about the quality of their daily motion, researchers have proposed a method using non-contact wearable sensors to estimate leg muscle activity. The optimized algorithm shows relatively high estimation accuracy and an acceptable delay for daily walking requirements.
To give people more specific information on the quality of their daily motion, it is necessary to continuously measure muscular activity during everyday occupations in an easy way. The traditional methods to measure muscle activity using a combination of surface electromyography (sEMG) sensors and optical motion capture system are expensive and not suitable for non-technical users and unstructured environment. For this reason, in our group we are researching methods to estimate leg muscle activity using non-contact wearable sensors, improving ease of movement and system usability. In a previous study, we developed a method to estimate muscle activity via only a single inertial measurement unit (IMU) on the shank. In this study, we describe a method to estimate muscle activity during walking via two IMU sensors, using an original sensing system and specifically developed estimation algorithms based on ANN techniques. The muscle activity estimation results, estimated by the proposed algorithm after optimization, showed a relatively high estimation accuracy with a correlation efficient of R-2 = 0.48 and a standard deviation STD = 0.10, with a total system average delay of 192 ms. As the average interval between different gait phases in human gait is 250-1000 ms, a 192 ms delay is still acceptable for daily walking requirements. For this reason, compared with the previous study, the newly proposed system presents a higher accuracy and is better suitable for real-time leg muscle activity estimation during walking.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available