4.6 Article

Flexible Machine Learning Algorithms for Clinical Gait Assessment Tools

Journal

SENSORS
Volume 22, Issue 13, Pages -

Publisher

MDPI
DOI: 10.3390/s22134957

Keywords

clinical gait analysis; gait partitioning; machine learning; wearables; inertial measurement units; sensors; deep neural networks; reinforcement learning

Funding

  1. Oro Muscles B.V. 9715 CJ Groningen, The Netherlands

Ask authors/readers for more resources

This study developed a novel machine learning algorithm and tested its validity for automated gait partitioning of laboratory-based and sensor-based gait data, showing low mean errors. By combining reinforcement learning with deep neural networks, significant reduction in the size of training datasets was achieved, providing high flexibility for end-users.
The current gold standard of gait diagnostics is dependent on large, expensive motion-capture laboratories and highly trained clinical and technical staff. Wearable sensor systems combined with machine learning may help to improve the accessibility of objective gait assessments in a broad clinical context. However, current algorithms lack flexibility and require large training datasets with tedious manual labelling of data. The current study tests the validity of a novel machine learning algorithm for automated gait partitioning of laboratory-based and sensor-based gait data. The developed artificial intelligence tool was used in patients with a central neurological lesion and severe gait impairments. To build the novel algorithm, 2% and 3% of the entire dataset (567 and 368 steps in total, respectively) were required for assessments with laboratory equipment and inertial measurement units. The mean errors of machine learning-based gait partitions were 0.021 s for the laboratory-based datasets and 0.034 s for the sensor-based datasets. Combining reinforcement learning with a deep neural network allows significant reduction in the size of the training datasets to <5%. The low number of required training data provides end-users with a high degree of flexibility. Non-experts can easily adjust the developed algorithm and modify the training library depending on the measurement system and clinical population.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available