4.6 Article

Prevention of droplet dispersal with 'e-mask': A new daily use endoscopic mask during bronchoscopy

Journal

RESPIROLOGY
Volume 27, Issue 10, Pages 863-873

Publisher

WILEY
DOI: 10.1111/resp.14321

Keywords

airborne particle; bronchoscopy; coronavirus disease; COVID-19; e-mask; prevention; respiratory protective devices

Funding

  1. FOREST/CREST (JST)
  2. KAKEN (JSPS) [18K15923, 21K07217]
  3. Yahoo Japan kikin
  4. Nagoya University

Ask authors/readers for more resources

This study evaluated the use of an e-mask during bronchoscopy and found that it significantly reduced the generation of airborne particles, while not increasing the risk of respiratory complications.
Background and objective Bronchoscopy is an airborne particle-generating procedure. However, few methods for safe bronchoscopy have been developed. To reduce airborne particles during bronchoscopy, we created an 'e-mask', which is a simple, disposable mask for patients. Our objective was to evaluate the e-mask's protective ability against airborne particles and to assess respiratory adverse events and complications. Methods Patients with stage 2-4 chronic obstructive pulmonary disease were excluded. We performed visualization and quantifying experiments on airborne particles with and without the e-mask. We prospectively evaluated whether wearing the e-mask during bronchoscopy was associated with the incidence of patients requiring >5 L/min oxygen to maintain >90% oxygen saturation, and patients with >45 mm Hg end-tidal carbon dioxide (EtCO2) elevation, in addition to complications, compared to historical controls. Results In the visualization experiment, more than ten thousand times of airborne particles were generated without the e-mask than with the e-mask. The volume of airborne particles was significantly reduced with the e-mask, compared to that without the e-mask (p = 0.011). Multivariate logistic regression analysis revealed that wearing the e-mask had no significant effect on the incidence of patients requiring >5 L/min oxygen to maintain >90% oxygen saturation, (p = 0.959); however, wearing the e-mask was a significant factor in >45 mm Hg EtCO2 elevation (p = 0.026). No significant differences in complications were observed between the e-mask and control groups (5.8% vs. 2.5%, p = 0.395). Conclusion Wearing the e-mask during bronchoscopy significantly reduced the generation of airborne particles during bronchoscopy without increasing complications.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available