Comparing radiolytic production of H2O2 and development of Zebrafish embryos after ultra high dose rate exposure with electron and transmission proton beams

Related references

Note: Only part of the references are listed.
Article Biology

Understanding the FLASH effect to unravel the potential of ultra-high dose rate irradiation

Houda Kacem et al.

Summary: Research on delivering radiation at ultra-high dose rates (UHDRs) has gained interest in the radiation sciences, particularly due to the promising FLASH effect observed. The potential clinical implications of FLASH radiotherapy (FLASH-RT) are significant, as it could enhance treatment efficacy while minimizing toxicity. Pioneering research teams are now investigating the mechanisms and clinical translation of the FLASH effect in order to advance this new field of study.

INTERNATIONAL JOURNAL OF RADIATION BIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

The current status of preclinical proton FLASH radiation and future directions

Eric S. Diffenderfer et al.

Summary: The review discusses the current status of proton FLASH experimental systems, highlighting both physical and biological results from preclinical studies. While no reproducible proton FLASH effect was observed in vitro, a significant sparing effect on normal tissue toxicity was seen in vivo with multiple proton FLASH irradiation systems. Future development areas focus on maximizing the therapeutic ratio between tumor and normal tissue response for clinical translation of proton FLASH radiation.

MEDICAL PHYSICS (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Validation of an ultrahigh dose rate pulsed electron beam monitoring system using a current transformer for FLASH preclinical studies

Patrik Goncalves Jorge et al.

Summary: In this study, commercially available beam current transformers (BCTs) were used as online monitoring tools to support CONV and UHDR irradiations in preclinical FLASH research. The results showed that the BCTs consistently determined the number of pulses, pulse width (PW), and pulse repetition frequency (PRF). The measured exit charge from the BCTs was correlated with the dose, with uncertainties of 0.5% in CONV mode and 3% in UHDR mode. The short- and long-term stabilities of the dose-to-charge ratio were below 1.6%.

MEDICAL PHYSICS (2022)

Article Oncology

In vivo validation and tissue sparing factor for acute damage of pencil beam scanning proton FLASH

Brita Singers Sorensen et al.

Summary: This study validated the effectiveness of proton FLASH technology in a mouse leg model and quantified the FLASH factor through full dose response curves.

RADIOTHERAPY AND ONCOLOGY (2022)

Article Oncology

Demonstration of the FLASH Effect Within the Spread-out Bragg Peak After Abdominal Irradiation of Mice

Tucker Evans et al.

Summary: The study investigated the effects of FLASH-level dose rates on normal tissue damage in mice, showing that mice exposed to FLASH dose rates had a higher LD50 value and improved survivability compared to mice exposed to conventional dose rates. The results suggest the potential benefits of combining the advantages of the Bragg peak with the normal tissue sparing benefits of FLASH treatments.

INTERNATIONAL JOURNAL OF PARTICLE THERAPY (2022)

Article Engineering, Biomedical

Al2O3:C optically stimulated luminescence dosimeters (OSLDs) for ultra-high dose rate proton dosimetry

Jeppe Brage Christensen et al.

Summary: The Al2O3:C optically stimulated luminescence detectors were found to be dose rate independent and applicable for radiobiological experiments in proton beams at ultra-high dose rates, with minimal deviation from nominal doses. Two setups for ultra-high dose rate experiments were presented, as well as a new method to extract beam spot size of narrow pencil beams.

PHYSICS IN MEDICINE AND BIOLOGY (2021)

Article Oncology

FLASH Proton Pencil Beam Scanning Irradiation Minimizes Radiation-Induced Leg Contracture and Skin Toxicity in Mice

Shannon Cunningham et al.

Summary: This study validated the reduction of normal tissue damage with FLASH radiotherapy compared to conventional treatment, and demonstrated the potential of PBS FLASH radiotherapy using proton pencil beam scanning technology in mice. The results support the role of FLASH radiotherapy in improving treatment outcomes and provide valuable data for further research.

CANCERS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Commissioning of a clinical pencil beam scanning proton therapy unit for ultra-high dose rates (FLASH)

Konrad P. Nesteruk et al.

Summary: This study aimed to adapt a former clinical pencil beam scanning gantry for proton FLASH research, achieving high dose rate irradiations by optimizing beamline parameters, characterizing dose monitors, and exploring scanning possibilities. The setup allowed for precise control of dose delivery in spot-scanning mode and enabled the investigation of a wide dose rate spectrum, making it a versatile test bench for FLASH research.

MEDICAL PHYSICS (2021)

Article Oncology

Electron dose rate and oxygen depletion protect zebrafish embryos from radiation damage

Joerg Pawelke et al.

Summary: The study demonstrated that the zebrafish embryo model is suitable for investigating the radiobiological response of high dose rate irradiation. It also highlighted the importance of pulse dose rate and partial oxygen pressure (pO(2)) as relevant parameters during radiation.

RADIOTHERAPY AND ONCOLOGY (2021)

Article Oncology

FLASH Proton Radiotherapy Spares Normal Epithelial and Mesenchymal Tissues While Preserving Sarcoma Response

Anastasia Velalopoulou et al.

Summary: The study shows that F-PRT has fewer toxicities and can spare normal tissues while providing antitumor efficacy equivalent to standard proton therapy. F-PRT reduced skin injury, stem cell depletion, inflammation, and late effects in murine experiments, and was effective in controlling sarcoma models.

CANCER RESEARCH (2021)

Article Oncology

Irradiation at Ultra-High (FLASH) Dose Rates Reduces Acute Normal Tissue Toxicity in the Mouse Gastrointestinal System

Jia-Ling Ruan et al.

Summary: The study showed that FLASH irradiation can spare mouse small intestinal crypts and reduce changes in gut microbiome composition compared with CONV irradiation. The higher the average dose rate, the larger the FLASH effect, which is also influenced by the temporal pulse structure of the delivery.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2021)

Article Oncology

Design, Implementation, and in Vivo Validation of a Novel Proton FLASH Radiation Therapy System

Eric S. Diffenderfer et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2020)

Article Multidisciplinary Sciences

Long-term neurocognitive benefits of FLASH radiotherapy driven by reduced reactive oxygen species

Pierre Montay-Gruel et al.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2019)

Article Oncology

Feasibility of proton FLASH effect tested by zebrafish embryo irradiation

Elke Beyreuther et al.

RADIOTHERAPY AND ONCOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

High dose-per-pulse electron beam dosimetry: Commissioning of the Oriatron eRT6 prototype linear accelerator for preclinical use

Maud Jaccard et al.

MEDICAL PHYSICS (2018)

Article Chemistry, Physical

Hydrogen peroxide production in the radiolysis of water with high radical scavenger concentrations

A Hiroki et al.

JOURNAL OF PHYSICAL CHEMISTRY A (2002)

Article Chemistry, Physical

Hydrogen peroxide yields in water radiolysis by high-energy ion beams at constant LET

V Wasselin-Trupin et al.

RADIATION PHYSICS AND CHEMISTRY (2002)