4.4 Article

Normative values of intra-bolus pressure and esophageal compliance based on 4D high-resolution impedance manometry

Journal

NEUROGASTROENTEROLOGY AND MOTILITY
Volume 34, Issue 10, Pages -

Publisher

WILEY
DOI: 10.1111/nmo.14423

Keywords

body compliance; distensibility index; intra-bolus pressure; intraluminal impedance

Funding

  1. National Institute of Diabetes and Digestive and Kidney Diseases [P01 DK117824]

Ask authors/readers for more resources

This study aimed to quantify normative values of phase-specific intra-bolus pressure (IBP) and esophageal distensibility using 4D analysis of high-resolution impedance manometry (HRIM). The results showed differences in esophageal pressure and esophagogastric junction distensibility index across different swallow phases.
Background This study aimed to quantify normative values of phase-specific intra-bolus pressure (IBP) and esophageal distensibility using 4D analysis of high-resolution-impedance manometry (HRIM). Methods HRIM studies of supine swallows from 34 normal controls were analyzed with respect to the four phases of bolus transit: (1) accommodation, (2) compartmentalization, (3) peristalsis/esophageal emptying, and (4) ampullary emptying. Phase-specific IBP, bolus volume, and distensibility index (DI) in the esophageal body and esophagogastric junction (EGJ) during phases 1-3 were extracted. Results The median (5-95th/IQR) IBP values were as follows: phase 1: 4.0 (-2.0-10.4/1.9-5.8) mmHg, phase 2: 5.7 (0.2-14.1/3.6-8.9) mmHg, and phase 3: 11.2 (2.9-19.4/7.7-15.1) mmHg. The median bolus volume calculated by integrating impedance planimetry cross-sectional areas was 4.1 ml during the compartmentalization phase. The EGJ-DI at max EGJ diameter during phase 2 and 3 was 2.8 (1.1-9.5/1.8-3.7) mm(2)/mmHg and 6.0 (3.2-20.3/5.1-7.8) mm(2)/mmHg, respectively. The phase 3 EGJ-DI values (6.0 (3.2-20.3/5.1-7.8) mm(2)/mmHg) were similar to those calculated using functional lumen imaging probe (FLIP) at the 60 ml volume on the same subjects (5.8 [3.5-7.2/5.0-6.4] mm(2)/mmHg). Conclusions and Inferences 4D-HRIM provides a standardized methodology to track the nadir impedance and provide measurements of IBP during maximal distention across phases 1-3 of bolus transit. Median IBP and delta IBP were different across the phases, supporting the need to define IBP by phase. Additionally, the EGJ-DI calculated during phase 3 was similar to the 60-ml EGJ-DI from FLIP in the same subjects suggesting that 4D-HRIM can quantify EGJ opening during primary peristalsis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available