4.5 Article

Evaluation of an ankle-foot orthosis effect on gait transitional stability during ramp ascent/descent

Journal

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING
Volume 60, Issue 7, Pages 2119-2132

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s11517-022-02587-z

Keywords

Gait; Stability margin; Ankle-foot orthosis; Loading and unloading; Ramp walk

Funding

  1. University of Engineering and Technology, Lahore, Pakistan
  2. Leeds, UK

Ask authors/readers for more resources

This study evaluates the effect of wearable ankle-foot orthoses (AFO) on balance control during ramp walking. The results show that wearing AFO decreases stability, but stability can be improved by adjusting AFO. The neuromotor outputs indicate compensatory interaction between limbs and larger stability margins compared to output margins.
Wearable ankle-foot orthoses (AFO) are widely prescribed clinically; however, their effect on balance control during ramp ascent/descent walk remains unknown. This study evaluates walking stability on a ramp during weight loading and unloading transitions of the stance phase with the effect of an adjustable AFO. An AFO is tuned firstly by tuning dorsiflexion only and then combining dorsi-plantarflexion adjustments. Gait stability is assessed from neuromotor input (centre-of-mass) and output (centre-of-pressure) responses obtained through motion-capture system and force platform. Stability margins are quantified from Nyquist and Bode methods illustrating the loading phase as stable and the unloading phase as unstable transition in all walking conditions. Further, a significant decrease in stability (p < 0.05) is observed by wearing AFO in its free mode which gets improved (p < 0.05) by tuning AFO. Results from neuromotor outputs also illustrated a strong interlimb correlation (p < 0.001), which implies a compensatory interaction between opposite limbs loading and unloading transitions. Neuromotor inputs illustrated unstable responses both in loading and unloading transitions and were observed to be greater in magnitudes compared with output margins. The overall results support the hypothesis that a wearable AFO affects gait stability during transitional phases, and by applying AFO adjustments, neuromotor balance control achieves stability margins closer to normal range.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available