Journal
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS
Volume 235, Issue 3, Pages 420-429Publisher
LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/XCS.0000000000000273
Keywords
-
Categories
Ask authors/readers for more resources
Previous research has shown that impedance planimetry-based FLIP measurements are associated with patient-reported outcomes after laparoscopic antireflux surgery. This study found that Toupet and Nissen fundoplications have different ideal distensibility ranges, which are associated with improved patient-reported outcomes.
BACKGROUND: Previous research has shown that impedance planimetry-based functional lumen imaging probe (FLIP) measurements are associated with patient-reported outcomes after laparoscopic antireflux surgery. We hypothesize that Nissen and Toupet fundoplications have different ideal FLIP profiles, such as distensibility. STUDY DESIGN: A retrospective review of a prospectively maintained quality database was performed. Patients who had FLIP measurements during fundoplications between 2013 and 2021 were included. Reflux Symptom Index, Gastroesophageal Reflux Disease-Health Related Quality of Life Questionnaire, and dysphagia score were collected for up to 2 years postoperatively. The Wilcoxon rank-sum test was used to compare FLIP measurements vs outcomes. RESULTS: Two hundred fifty patients (171 Toupet, 79 Nissen) were analyzed. Distensibility ranges were categorized as tight, ideal, or loose. The ideal distensibility index range of Toupet patients with the 30- and 40-mL balloon fills were 2.6 to 3.7 mm(2)/mmHg. This range was associated with less dysphagia at 1 year compared with the tight group (p = 0.02). For Nissen patients, the 30- and 40-mL ideal threshold was a distensibility index of >= 2.2 mm(2)/mmHg. Patients with distensibility exceeding this threshold had a better quality of life than the tight group, reporting better Gastroesophageal Reflux Disease-Health Related Quality of Life Questionnaire (p = 0.02) and lower dysphagia scores (p = 0.01) at 2 years. CONCLUSIONS: Impedance planimetry revealed different ideal distensibility ranges after Toupet and Nissen fundoplications that are associated with improved patient-reported outcomes, suggesting that intraoperative FLIP has the potential to tailor fundoplication. (C) 2022 by the American College of Surgeons. Published by Wolters Kluwer Health, Inc. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available