4.5 Article Proceedings Paper

Impedance Planimetry (Endoflip) and Ideal Distensibility Ranges for Optimal Outcomes after Nissen and Toupet Fundoplication

Journal

JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS
Volume 235, Issue 3, Pages 420-429

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/XCS.0000000000000273

Keywords

-

Categories

Ask authors/readers for more resources

Previous research has shown that impedance planimetry-based FLIP measurements are associated with patient-reported outcomes after laparoscopic antireflux surgery. This study found that Toupet and Nissen fundoplications have different ideal distensibility ranges, which are associated with improved patient-reported outcomes.
BACKGROUND: Previous research has shown that impedance planimetry-based functional lumen imaging probe (FLIP) measurements are associated with patient-reported outcomes after laparoscopic antireflux surgery. We hypothesize that Nissen and Toupet fundoplications have different ideal FLIP profiles, such as distensibility. STUDY DESIGN: A retrospective review of a prospectively maintained quality database was performed. Patients who had FLIP measurements during fundoplications between 2013 and 2021 were included. Reflux Symptom Index, Gastroesophageal Reflux Disease-Health Related Quality of Life Questionnaire, and dysphagia score were collected for up to 2 years postoperatively. The Wilcoxon rank-sum test was used to compare FLIP measurements vs outcomes. RESULTS: Two hundred fifty patients (171 Toupet, 79 Nissen) were analyzed. Distensibility ranges were categorized as tight, ideal, or loose. The ideal distensibility index range of Toupet patients with the 30- and 40-mL balloon fills were 2.6 to 3.7 mm(2)/mmHg. This range was associated with less dysphagia at 1 year compared with the tight group (p = 0.02). For Nissen patients, the 30- and 40-mL ideal threshold was a distensibility index of >= 2.2 mm(2)/mmHg. Patients with distensibility exceeding this threshold had a better quality of life than the tight group, reporting better Gastroesophageal Reflux Disease-Health Related Quality of Life Questionnaire (p = 0.02) and lower dysphagia scores (p = 0.01) at 2 years. CONCLUSIONS: Impedance planimetry revealed different ideal distensibility ranges after Toupet and Nissen fundoplications that are associated with improved patient-reported outcomes, suggesting that intraoperative FLIP has the potential to tailor fundoplication. (C) 2022 by the American College of Surgeons. Published by Wolters Kluwer Health, Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available