4.6 Article

Agreement and Precision of Deuterium Dilution for Total Body Water and Multicompartment Body Composition Assessment in Collegiate Athletes

Journal

JOURNAL OF NUTRITION
Volume 152, Issue 9, Pages 2048-2059

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1093/jn/nxac116

Keywords

spectrophotometry; bioelectrical impedance; body composition; deuterium isotope dilution; total body water

Funding

  1. NCI [CA71789]

Ask authors/readers for more resources

This study investigated the accuracy and precision of total body water estimates using different measurement conditions and techniques. It found that small differences in total body water measurement could lead to significant disparities in 2C models, with 5C models partially mitigating these differences.
Background Deuterium oxide (D2O) dilution is the criterion method for total body water (TBW) measurement, but results may vary depending on the specimen type, analysis method, and analyzing laboratory. Bioelectrical impedance (BIA) estimates TBW, but results may vary by device make and model. Objectives We investigated the accuracy and precision of TBW estimates and how measurement conditions affected the accuracy of body composition using multicompartment body composition models. Methods Eighty collegiate athletes received duplicate TBW measures acquired from 3 BIA devices (S10, SFB7, and SOZO) and from unique D2O combinations of specimen type (saliva, urine), analysis methodology [Fourier transform infrared spectrophotometry (FTIR), isotope-ratio mass spectrometry (IRMS)], and 3 different laboratories. TBW measures were substituted into 2-compartment (2C) and 5-compartment (5C) body composition models. Criterion measures were compared using Lin's concordance correlation coefficient cutoff of poor (<0.90), moderate (0.90-0.95), substantial (0.95-0.99), and almost perfect (>0.99). Results Fifty-one participants (26 female) completed the protocol. Using IRMS saliva as the criterion TBW, all other measures produced a substantial or almost perfect agreement, except for SFB7 (poor) and SOZO (moderate). The 2C body composition measures using D2O and BIA produced poor agreement except for moderate agreement for lab 3 FTIR saliva. The 5C body composition measures using D2O produced a substantial agreement, whereas the BIA device S10 and SOZO had a moderate agreement, while the SFB7 had a poor agreement to the criterion. Test-retest precision varied between techniques from 0.3% to 1.2% for TBW. Conclusions Small differences in TBW measurement led to significant differences in 2C models. The 5C models partially mitigate differences seen in 2C models when different TBW measures are used. Interchanging TBW measures in multicompartment models can be problematic and should be performed with these considerations.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available