Wearable sensor device-based detection of decreased heart rate variability in Parkinson's disease

Journal

JOURNAL OF NEURAL TRANSMISSION
Volume 129, Issue 10, Pages 1299-1306

Publisher

SPRINGER WIEN
DOI: 10.1007/s00702-022-02528-y

Keywords

Parkinson's disease; Wearable sensor device; Heart rate variability; Autonomic dysfunction; Autonomic nervous system

Funding

  1. JSPS KAKENHI [20K16597, 20H00527]
  2. Japan Agency for Medical Research and Development [JP21lk0201124, JP20dm0107155, JP21dk0207052]
  3. Ministry of Health, Labor, and Welfare of Japan

Ask authors/readers for more resources

This study examined the HRV in Parkinson's disease patients using wearable sensors and found that the minimum values of SDNN and CVRR were significantly decreased in PD. Analyzing these minimum values in long-term recordings may be appropriate for detecting the decrease in HRV in PD.
The evidence that heart rate variability (HRV) decreases during early Parkinson's disease (PD) largely depends on electrocardiogram data. In this study, we examined HRV in PD using wearable sensors and assessed various evaluation methods for detecting disease-related alterations. We evaluated 27 patients with PD and 23 disease controls. The wearable sensors POLAR V800 HR and POLAR H10 were used for the HRV measurements. The participants wore the two sensors for approximately 24 h, and long-term HRV data were acquired. We analyzed the standard deviation of normal R-R intervals (SDNN) and coefficient of variation of R-R intervals (CVRR) for every 100 consecutive beats. Focusing on the fluctuation of SDNN and CVRR, we extracted the minimum, first decile, first quartile, and median values of SDNN and CVRR. The area under the receiver operating characteristic curve (AUC) for each HRV parameter was calculated to differentiate PD from the disease controls. The minimum values of SDNN and CVRR had the highest AUC (SDNN: AUC 0.90, 95% confidence interval [CI] 0.78-0.96; CVRR: AUC 0.90, CI 0.76-0.96) among the evaluation methods tested. The minimum values of SDNN and CVRR were significantly decreased in PD (SDNN: 9.5 +/- 4.0 ms vs. 4.4 +/- 2.0 ms, p < 0.0001; CVRR: 1.15 +/- 0.33% vs. 0.65 +/- 0.24%, p < 0.0001). We detected decreased HRV in PD using wearable sensors. Analyzing the minimum values of the HRV parameter in long-term recordings appears to be appropriate for detecting the decrease in HRV in PD.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available