4.2 Article

An Effective Chromatographic Method for Simultaneous Quantification of Antidiabetic Drugs Alogliptin Benzoate and Pioglitazone HCl in Their Tablet Dosage Form: Implementation to In vitro Dissolution Studies and Uniformity of Dosage Unit

Journal

JOURNAL OF CHROMATOGRAPHIC SCIENCE
Volume 61, Issue 8, Pages 705-716

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1093/chromsci/bmac065

Keywords

-

Ask authors/readers for more resources

A cost-effective and precise RP-HPLC method was developed and validated for the analysis of Alogliptin and Pioglitazone in patients with Type 2 diabetes. The method showed satisfactory results in various tests and can be used for quality control.
In patients with Type 2 diabetes, a combination of Alogliptin and Pioglitazone medications, together with diet and physical activity, are used to improve glycemic control. Eco-friendly, cost-effective, and precise stability-indicating RP-HPLC method was developed and validated for the identification and quantification of Alogliptin and Pioglitazone in their tablet dosage form, as well as implementation to in vitro dissolution studies and uniformity of dosage unit. Isocratic separation is conducted at ambient temperature on the InertSustain C18 Analytical Column (150 x 4.6 mm, 5 mu m) using mobile phase comprising 50 mM of ammonium dihydrogen phosphate and 5.0 mM of heptane sulfonic acid:acetonitrile (45:55, v/v) at a flow rate of 1.3 mL/minute. Calibration curves are conducted in the linearity range of 1-40 mu g/mL of Alogliptin and 2.5-75 mu g/mL of Pioglitazone with a correlation value >0.9995 and satisfactory recovery findings between 99 and 100%. The degraded samples are analyzed under relevant stress conditions as acidity, alkalinity, thermal and oxidation. The active components in finished products were subjected to a content uniformity test, which showed that they achieved the declared claim's acceptance standards (85-115%). Comparative in vitro dissolution studies are performed for generic products Inhibazone 12.5/30 mg FCT and Inhibazone 25/15 mg FCT against innovator products Oseni 12.5/30 mg FCT and Oseni 25/15 mg FCT at suitable FDA dissolution medium and different USP dissolution media and the results are similar. The metrics of the designed method were assessed according to ICH requirements, and all metrics, such as system suitability, linearity, recovery, robustness, LOD, LOQ, specificity and precision, were found to be within required tolerances and no overlapping was found for degradation peaks. Thence, the method can be used in quality control for the analysis of raw material, bulk, finish and stability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available