4.7 Article

Sulphurous air pollutants and exposure events of workers in thermal-mineral springs: a case study of Contursi Terme (Salerno, Italy)

Journal

ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH
Volume 30, Issue 2, Pages 3112-3120

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s11356-022-22432-y

Keywords

Occupational health; Pollutant exposure; Air monitoring; Thermal-mineral springs

Ask authors/readers for more resources

Thermo-mineral springs in Salerno, Italy, have beneficial effects on human health, but also contain potentially toxic compounds such as hydrogen sulphide (H2S) and sulphur dioxide (SO2). This study monitored the air concentrations of H2S and SO2 in the thermal springs of Contursi Terme for 4 months to assess workers' exposure to these pollutants. It was found that the concentrations of SO2 varied seasonally, while H2S concentrations were higher outdoors than indoors. Further investigations are needed to ensure workers' safety in this thermal spring workplace.
Thermo-mineral springs are widely spread over the volcanic areas of Salerno, a city in southern Italy. Although the water of thermal structures provides beneficial effects on human health, the air is characterized by the presence of potentially toxic compounds, such as hydrogen sulphide (H2S) and sulphur dioxide (SO2). Exposure to sulphurous compounds may have detrimental effects on human health, with asthma being the most common. In this study, air concentrations of H2S and SO2 in the thermal springs of Contursi Terme (Salerno, Italy) were monitored for 4 months (using both active and passive sampling), along with the chemical and microclimatic characterization of thermal water, to assess workers' exposure to these pollutants. An in-depth characterization of indoor air at the springs is paramount to establish emission control limits for occupational exposure and to take protective measures. The air concentration of SO2 varied from 0.11 +/- 0.02 to 0.91 +/- 0.02 mg/m(3), following a seasonal pattern (higher values in winter and lower in spring). Conversely, indoor H2S concentrations did not vary significantly with time, but outdoor levels (from 0.40 +/- 0.03 to 1.90 +/- 0.03 mg/m(3)) were always higher than indoor ones (from 0.11 +/- 0.03 to 0.56 +/- 0.03 mg/m(3)). Not negligible air concentrations of these pollutants were detected in this thermal spring workplace, so further investigations are needed to ensure workers' safety.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available