4.7 Article

Effect of Macrotroponin in a Cohort of Community Patients with Elevated Cardiac Troponin

Journal

CLINICAL CHEMISTRY
Volume 68, Issue 10, Pages 1261-1271

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1093/clinchem/hvac118

Keywords

-

Ask authors/readers for more resources

Macrotroponin is associated with multifactorial or indeterminate causes of troponin elevation in community patients. Better diagnostic performance was observed in patients without macrotroponin when repeat testing was conducted using different hs-cTnI assays. Participants with macrotroponin had better overall survival.
Background Macrotroponin is an important cause of discrepancy between current high-sensitivity cardiac troponin (hs-cTn) assays, however, its clinical significance is unclear. This study examined the effects of macrotroponin and repeat testing by different hs-cTnI assays in a cohort of community patients with elevated hs-cTnI. Methods The first residual serum specimen from each patient in the community admitted to hospital with elevated hs-cTnI (Siemens hs-cTnI Centaur) was retested after immunoglobulin depletion and by 5 other hs-cTn assays. Low recovery of cTnI (<40%) following immunoglobulin depletion was considered as macrotroponin. A retrospective chart review was performed for these participants. Investigator-adjudicated diagnosis served as the reference standard. Results In our cohort of community patients with elevated troponin (n = 188), participants with macrotroponin (n = 99) often had a multifactorial or indeterminate myocardial injury (56% vs 25%) and were less likely to have acute coronary syndrome (9% vs 28%). On repeat testing of cTn on other platforms, better diagnostic performance (c-statistics) for ischemic and non-ischemic cardiac causes was observed on the Beckman Access hs-cTnI (0.74; 95% confidence interval [CI] 0.67-0.81) or the Abbott hs-cTnI Architect (0.75; CI 0.68-0.82) compared to the Siemens hs-cTnI Vista (0.62; CI 0.54-0.70; P < 0.05). This could be attributed to differences in assay reactivity for macrotroponin. Interestingly, better diagnostic performance was observed in patients without macrotroponin. Although a small number of deaths occurred (n = 16), participants with macrotroponin had better overall survival. Conclusions In the low-risk setting, the presence of macrotroponin was clinically associated with multifactorial or indeterminate causes of troponin elevation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available