4.7 Article

Ventilation impacts on infection risk mitigation, improvement of environmental quality and energy efficiency for subway carriages

Related references

Note: Only part of the references are listed.
Article Construction & Building Technology

Evaluation of different air distribution systems in a commercial airliner cabin in terms of comfort and COVID-19 infection risk

Mingxin Liu et al.

Summary: This study evaluated the performance of a novel displacement ventilation (DV) system and a traditional mixing ventilation (MV) system in an airliner cabin, and found that polydisperse particles should be used to calculate the risk of infection in airliner cabins, with lower infection risk with DV compared to MV during the early stages of the COVID-19 pandemic.

BUILDING AND ENVIRONMENT (2022)

Article Transportation

An analysis of tripadvisor reviews of 127 urban rail transit networks worldwide

Viriya Taecharungroj

Summary: This research uncovered experiential dimensions of URT travellers from TripAdvisor reviews and compared URTNs worldwide using unsupervised machine learning technique. The analysis identified eleven experiential dimensions and factors that drive positive and negative experiences. This study presents a rapid and insightful method for assessing traveller experiences, which can be used by URTNs worldwide for service improvement.

TRAVEL BEHAVIOUR AND SOCIETY (2022)

Review Construction & Building Technology

A critical review on the adaptability of ventilation systems: Current problems, solutions and opportunities

O. Seuntjens et al.

Summary: Currently, many buildings are demolished before reaching their technical lifespan due to the inability to meet the changing needs of owners and users. To address this waste, the construction industry is shifting towards adaptable building practices. Comfort systems in buildings play a critical role in ensuring occupant health and comfort in flexible scenarios. However, traditional approaches to ventilation lack adaptability, and there is a lack of specific guidelines for designing adaptable ventilation systems.

BUILDING AND ENVIRONMENT (2022)

Article Construction & Building Technology

Integrated maintenance planning approach to optimize budget allocation for subway operating systems

Omar El Hamshary et al.

Summary: This research aims to develop a risk-based optimization framework for optimizing the maintenance performance and budget allocation of subway systems. The framework provides optimal budget allocation for each subway system, assisting subway asset managers in decision-making process.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2022)

Article Environmental Sciences

A stratum ventilation system for pollutants and an improved prediction model for infection in subway cars

Yanhui Mao et al.

Summary: A study on pollutant concentrations in subway cars of Ningbo Rail Transit Line 2 was conducted, proposing a stratum ventilation technology to improve air quality. Computational fluid dynamics showed that subway cars with stratum ventilation form an air curtain, effectively enhancing air quality within the breathing area of seated passengers. The Wells-Riley model was enhanced to predict airborne infection probability, revealing that stratum ventilation technology reduces the risk of pathogenic infection among seated passengers compared to conventional subway cars.

ATMOSPHERIC POLLUTION RESEARCH (2022)

Article Construction & Building Technology

Using revised ADPIs to identify an optimum positioning for installation of reversible room air-conditioners in bedroom for maximum thermal comfort

Xin Wang et al.

Summary: This study is the first attempt to investigate the optimal positioning for installation of reversible RACs in a representative bedroom. Through CFD simulations and experiments, it was found that slightly higher air diffusion performance indices (ADPIs) can be obtained when the reversible RAC is installed at high level on the longer side of the bedroom.

BUILDING AND ENVIRONMENT (2021)

Article Construction & Building Technology

Experimental investigation on the ventilation performance of diffuse ceiling ventilation in heating conditions

Pei Peng et al.

Summary: The study investigates the performance of diffuse ceiling ventilation (DCV) in heating mode through fullscale chamber experiments. It shows that increased air change rates can improve indoor air quality, while having little impact on ventilation effectiveness. The intensity of internal heat sources and the type of contaminant sources strongly influence DCV's ventilation effectiveness, with the effect of exhaust positions depending on the presence of internal heat sources.

BUILDING AND ENVIRONMENT (2021)

Review Construction & Building Technology

Application of computational fluid dynamics in subway environment without fire and smoke-Literature review

Yunlong Peng et al.

Summary: This review systematically presents the recent applications of Computational Fluid Dynamics (CFD) in the subway environment, focusing on three scenarios including subway tunnels, stations, and passenger cabins, and analyzing two objective parameters particulate matter and energy savings. The boundary conditions, validation methods, turbulence models, and mesh information are summarized for predicting future perspectives on the subway environment.

BUILDING AND ENVIRONMENT (2021)

Article Construction & Building Technology

Experimental investigation of air distribution in an airliner cabin mockup with displacement ventilation

Mingxin Liu et al.

Summary: The study found that airflow and contaminant concentration distributions in commercial airliner cabins are crucial for creating a comfortable and healthy environment. However, the airflow is predominantly controlled by natural convection, and vertical temperature stratification may lead to passenger discomfort.

BUILDING AND ENVIRONMENT (2021)

Article Construction & Building Technology

Multi-objective optimization of a time-delay compensated ventilation control system in a subway facility - A harmony search strategy

Jorge Loy-Benitez et al.

Summary: This study introduces an adaptive ventilation control system for indoor air quality management in subway stations, which dynamically regulates the setpoint of PM10 concentration and incorporates a Smith predictor to improve energy efficiency and reduce health risks. Comparison with conventional systems demonstrated potential energy savings under good outdoor air quality conditions and a decrease in health risk levels from unhealthy to moderate under unhealthy conditions.

BUILDING AND ENVIRONMENT (2021)

Article Construction & Building Technology

Occupant-density-detection based energy efficient ventilation system: Prevention of infection transmission

Junqi Wang et al.

Summary: This study proposes a smart low-cost ventilation control strategy based on occupant density detection algorithm, which automatically adjusts ventilation rate to save energy and reduce infection transmission probability. Case studies show that the strategy can achieve 11.7% energy savings while lowering the infection probability to 2%.

ENERGY AND BUILDINGS (2021)

Article Environmental Sciences

Tracing surface and airborne SARS-CoV-2 RNA inside public buses and subway trains

Teresa Moreno et al.

Summary: A study on public transport in Barcelona during the summer of 2020 found traces of SARS-CoV-2 viral RNA in surface and air samples, with more viral remnants on bus surfaces compared to trains. Although signs of viral RNA were detected, they were considered unlikely to be infectious. Vigilant attention to ventilation systems and regular disinfection of vehicles are necessary to effectively eliminate viral traces, especially during peak COVID-19 periods.

ENVIRONMENT INTERNATIONAL (2021)

Article Environmental Sciences

Air change rate effects on the airborne diseases spreading in Underground Metro wagons

Mostafa El-Salamony et al.

Summary: The study investigates the impact of fresh air change rates inside passengers' wagons for Underground Metro on airborne diseases like COVID-19. It was found that open windows are favored to decrease infection spreading potential and higher air change rates can also help reduce transmission.

ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH (2021)

Article Construction & Building Technology

Influence of air inlet/outlet arrangement of displacement ventilation on local environment control for unearthed relics within site museum

Xilian Luo et al.

Summary: Displacement ventilation system is a proven method to save energy and control the local preservation environment for unearthed relics in site museums. Adjustments in air inlet/outlet arrangement and earthen site temperature can improve system performance, reduce energy consumption and achieve environmental control.

ENERGY AND BUILDINGS (2021)

Article Construction & Building Technology

Sustainable material choice for construction projects: A Life Cycle Sustainability Assessment framework based on BIM and Fuzzy-AHP

Karoline Figueiredo et al.

Summary: Construction industry is seeking sustainable solutions to reduce negative impacts, and researchers have proposed a decision-making framework integrating Life Cycle Sustainability Assessment, Multi-Criteria Decision Analysis, and Building Information Modeling for material selection in buildings.

BUILDING AND ENVIRONMENT (2021)

Article Construction & Building Technology

A thermal comfort field study on subway passengers during air-conditioning season in Beijing

Song Pan et al.

SUSTAINABLE CITIES AND SOCIETY (2020)

Article Construction & Building Technology

Integrated design for underground space environment control of subway stations with atriums using piston ventilation

Yueming Wen et al.

INDOOR AND BUILT ENVIRONMENT (2020)

Article Construction & Building Technology

Study on the subway environment induced by moving train using Gaussian distributed momentum source theory method

Chen Ren et al.

INDOOR AND BUILT ENVIRONMENT (2019)

Article Construction & Building Technology

A dynamic gain-scheduled ventilation control system for a subway station based on outdoor air quality conditions

Jorge Loy-Benitez et al.

BUILDING AND ENVIRONMENT (2018)

Article Construction & Building Technology

Air diffusion performance index (ADPI) of overhead-air-distribution at low cooling loads

Shichao Liu et al.

ENERGY AND BUILDINGS (2017)

Review Environmental Sciences

Air quality inside subway metro indoor environment worldwide: A review

Bin Xu et al.

ENVIRONMENT INTERNATIONAL (2017)

Article Construction & Building Technology

Modeling subway air flow using CFD

Fernando E. Camelli et al.

TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY (2014)

Article Construction & Building Technology

Application of the analytic hierarchy process (AHP) in multi-criteria analysis of the selection of intelligent building systems

Johnny K. W. Wong et al.

BUILDING AND ENVIRONMENT (2008)

Article Construction & Building Technology

Risk of indoor airborne infection transmission estimated from carbon dioxide concentration

SN Rudnick et al.

INDOOR AIR (2003)

Article Energy & Fuels

Ventilation of enclosed train compartments in Hong Kong

WK Chow

APPLIED ENERGY (2002)