Related references
Note: Only part of the references are listed.A new interspinous process distraction device BacFuse in the treatment of lumbar spinal stenosis with 5 years follow-up study
Mengmeng Chen et al.
MEDICINE (2020)
Effect of different designs of interspinous process devices on the instrumented and adjacent levels after double-level lumbar decompression surgery: A finite element analysis
Hao-Ju Lo et al.
PLOS ONE (2020)
Decompression Surgery versus Interspinous Devices for Lumbar Spinal Stenosis: A Systematic Review of the Literature
Jennifer Tram et al.
ASIAN SPINE JOURNAL (2020)
Finite element analysis and design of an interspinous device using topology optimization
Li-Xin Guo et al.
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING (2019)
Application of an interspinous process device after minimally invasive lumbar decompression could lead to stress redistribution at the pars interarticularis: a finite element analysis
Hao-Ju Lo et al.
BMC MUSCULOSKELETAL DISORDERS (2019)
A comparison of the influence of three different lumbar interbody fusion approaches on stress in the pedicle screw fixation system: Finite element static and vibration analyses
Wei Fan et al.
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING (2019)
Comparative effectiveness and safety of posterior lumbar interbody fusion, Coflex, Wallis, and X-stop for lumbar degenerative diseases: A systematic review and network meta-analysis
Zhuomao Mo et al.
CLINICAL NEUROLOGY AND NEUROSURGERY (2018)
Biomechanical analysis of a new lumbar interspinous device with optimized topology
Chen-Sheng Chen et al.
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING (2018)
Interspinous process devices for treatment of degenerative lumbar spine stenosis: A systematic review and meta-analysis
Arthur Werner Poetscher et al.
PLOS ONE (2018)
Effect of Lumbar Lordosis on the Adjacent Segment in Transforaminal Lumbar Interbody Fusion: A Finite Element Analysis
Xin Zhao et al.
WORLD NEUROSURGERY (2018)
Biomechanical Analysis of Lateral Lumbar Interbody Fusion Constructs with Various Fixation Options: Based on a Validated Finite Element Model
Zhenjun Zhang et al.
WORLD NEUROSURGERY (2018)
The Role of Posterior Screw Fixation in Single-Level Transforaminal Lumbar Interbody Fusion During Whole Body Vibration: A Finite Element Study
Wei Fan et al.
WORLD NEUROSURGERY (2018)
Biomechanical evaluation of a novel pedicle screw-based interspinous spacer: A finite element analysis
Hsin-Chang Chen et al.
MEDICAL ENGINEERING & PHYSICS (2017)
Biomechanical Effects of the Geometry of Ball-and-Socket Artificial Disc on Lumbar Spine
Jisoo Choi et al.
SPINE (2017)
Interspinous process devices(IPD) alone versus decompression surgery for lumbar spinal stenosis(LSS): A systematic review and meta-analysis of randomized controlled trials
Xing-wen Zhao et al.
INTERNATIONAL JOURNAL OF SURGERY (2017)
Failure rates and complications of interspinous process decompression devices: a European multicenter study
Roberto Gazzeri et al.
NEUROSURGICAL FOCUS (2015)
Comparing Cost-effectiveness of X-Stop With Minimally Invasive Decompression in Lumbar Spinal Stenosis A Randomized Controlled Trial
Greger Lonne et al.
SPINE (2015)
Interspinous process device versus standard conventional surgical decompression for lumbar spinal stenosis: randomized controlled trial
Wouter A. Moojen et al.
BMJ-BRITISH MEDICAL JOURNAL (2013)
Biomechanical effect after Coflex and Coflex rivet implantation for segmental instability at surgical and adjacent segments: a finite element analysis
Cheng-Chan Lo et al.
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING (2011)
Biomechanical comparison of single-level posterior versus transforaminal lumbar interbody fusions with bilateral pedicle screw fixation: segmental stability and the effects on adjacent motion segments Laboratory investigation
Hong Bo Sim et al.
JOURNAL OF NEUROSURGERY-SPINE (2010)
Dynamic interspinous process stabilization: review of complications associated with the X-Stop device
Christian Bowers et al.
NEUROSURGICAL FOCUS (2010)
High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis
Olaf J. Verhoof et al.
EUROPEAN SPINE JOURNAL (2008)
Hybrid multidirectional test method to evaluate spinal adjacent-level effects
Manohar M. Panjabi
CLINICAL BIOMECHANICS (2007)
One-year outcome evaluation after interspinous implantation for degenerative spinal stenosis with segmental instability
Doo-Sik Kong et al.
JOURNAL OF KOREAN MEDICAL SCIENCE (2007)
The effect of an interspinous process implant on facet loading during extension
CM Wiseman et al.
SPINE (2005)
Re. The effect of an interspinous implant on intervertebral disc pressures
TE Whitesides
SPINE (2003)