4.7 Article

Standardisation of ACPA tests: evaluation of a new candidate reference preparation

Journal

ANNALS OF THE RHEUMATIC DISEASES
Volume 81, Issue 10, Pages 1379-1384

Publisher

BMJ PUBLISHING GROUP
DOI: 10.1136/annrheumdis-2021-221849

Keywords

anti-citrullinated protein antibody; reference material; NIBSC; standardization

Categories

Ask authors/readers for more resources

Commercial assays measuring antibodies to citrullinated protein/peptide (ACPA) show poor quantitative agreement, as they have not adopted an international standard. The candidate NIBSC 18/204 standard improved the standardization of most ACPA assays.
Introduction Commercial assays measuring antibodies to citrullinated protein/peptide (ACPA) show poor quantitative agreement. The diagnostic industry has never adopted the International Union of Immunological Societies-Centers for Disease Control and Prevention (IUIS-CDC) ACPA reference standard. Recently, the National Institute for Biological Standards and Control (NIBSC) prepared a new candidate ACPA standard (18/204). We evaluated both reference materials using different commercially available ACPA assays. Materials and methods This is an international study in which the NIBSC candidate ACPA standard and the IUIS-CDC ACPA reference material were analysed together with 398 diagnostic samples from individuals with rheumatoid arthritis (RA) and in 1073 individuals who did not have RA using nine commercial ACPA assays. Results For both reference materials and samples from individuals with RA and individuals who did not have RA, there were large differences in quantitative ACPA results between assays. For most assays, values for the IUIS-CDC standard were lower than values for NIBSC 18/204 and the IUIS-CDC/NIBSC ratio was comparable for several, but not all assays. When NIBSC 18/204 was used as a calibrator, an improvement in alignment of ACPA results across several of the evaluated assays was obtained. Moreover, NIBSC 18/204 could align clinical interpretation for some but not all assays. Conclusion Adoption of an international standard for ACPA determination is highly desirable. The candidate NIBSC 18/204 standard improved the standardisation and alignment of most ACPA assays and might therefore be recommended to be used as reference in commercial assays.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available