4.8 Article

Anisotropic mechanical and mass-transport performance of Ti6Al4V plate-lattice scaffolds prepared by laser powder bed fusion

Journal

ACTA BIOMATERIALIA
Volume 148, Issue -, Pages 374-388

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.actbio.2022.06.016

Keywords

Plate lattice scaffolds; Laser powder bed fusion; Anisotropic performance; Numerical simulation; Experimental verification

Funding

  1. National Natural Science Founda- tion of China [51922044]
  2. Key -Area Research and Develop- ment Program of Guangdong Province [2020B090923001]
  3. Academic Frontier Youth Team [2018QYTD04]
  4. Huazhong University of Science and Technology

Ask authors/readers for more resources

This study proposes body-centered-cubic and face-centered-cubic plate lattice scaffolds with mechanical and mass-transport performance close to human bones. A valid regulation strategy is put forward to modulate their performance. The findings provide guidance for advanced scaffold designing.
In bone scaffolds, the mechanical performance provides the load-bearing capability, and the mass -transport performance presented as permeability dominates the nutrients/oxygen transportation effi-ciency. Body-centered-cubic and face-centered-cubic plate lattice scaffolds with mechanical and mass -transport performance close to human bones are proposed in the present study. The regular periodic architecture and plane-stress state of the plate lattice scaffolds not only provide them with advanced mechanical properties but avoid stress concentration that ubiquitously exists in traditional truss lattice scaffolds. By investigating the anisotropic mechanical and mass-transport performance of plate lattice scaffolds, a valid regulation strategy is put forward to modulate their performance without changing the volume fraction and architecture, providing an alternative scheme for biomedical scaffold design. Both computational and experimental results demonstrate that body-centered-cubic and face-centered-cubic plate lattice scaffolds possess appropriate mechanical and mass-transport performance close to human bones. In addition, tuning ranges of the mechanical and mass-transport performance of plate lattice scaf-folds for different orientations are up to 40% and 45%, respectively. These findings could provide valuable references for the extensive applications of plate lattice scaffolds in bone tissue engineering.Statement of significanceIn bone tissue engineering, scaffolds with low density, high strength, and proper permeability are of con-stant request. The present study proposes body-centered-cubic and face-centered-cubic plate lattice scaf-folds with mechanical and mass-transport performance close to human bones. The deformation mecha-nisms and mass-transport characteristics of plate lattice scaffolds for different orientations are revealed. In addition, a valid regulation strategy is put forward to modulate the mechanical and mass-transport performance of plate lattice scaffolds without changing their volume fraction and architecture, provid-ing an alternative scheme for biomedical scaffold design. We believe that these findings could provide significant guidance for the simultaneous improvements of advanced scaffold designing.(c) 2022 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available