4.3 Article

Sonographic differences in carpal tunnel syndrome with normal and abnormal nerve conduction studies

Journal

JOURNAL OF CLINICAL NEUROSCIENCE
Volume 34, Issue -, Pages 77-80

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.jocn.2016.05.024

Keywords

Carpal tunnel syndrome; Cross-sectional area; Median nerve; Nerve conduction studies; Ultrasound

Ask authors/readers for more resources

We evaluated the differences in sonographic parameters in carpal tunnel syndrome (CTS) patients with normal and mildly abnormal nerve conduction studies (NCS). This was a prospective cross-sectional study. We assessed 169 wrists (101 patients) with a clinical diagnosis of carpal tunnel syndrome (CTS), as well as 20 healthy controls (40 wrists). 49 wrists were classified as mild NCS-positive and 38 as NCS-negative based on our laboratory NCS normal values. The cross-sectional area (CSA) of the median nerve at the carpal tunnel inlet and mid-forearm were measured and the wrist-to -forearm ratio (WFR) was calculated. 26% of the NCS-negative group had abnormal CSA. The CSA and WFR also differed significantly between the two groups. There was significant correlation between the sonographic and electrophysiologic variables. Ultrasound was diagnostic for CTS in a third of the NCS-negative wrists. Ultrasound may be useful in clinical CTS patients with normal or borderline NCS. (C) 2016 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available