4.7 Article

Low DHEAS: A Sensitive and Specific Test for the Detection of Subclinical Hypercortisolism in Adrenal Incidentalomas

Journal

JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM
Volume 102, Issue 3, Pages 786-792

Publisher

ENDOCRINE SOC
DOI: 10.1210/jc.2016-2718

Keywords

-

Funding

  1. National Institute for Health Research Cambridge Biomedical Research Centre

Ask authors/readers for more resources

Context: Subclinical hypercortisolism (SH) occurs in 5% to 30% of adrenal incidentalomas (AIs). Common screening tests for adrenocorticotropin-independent hypercortisolism have substantial false-positive rates, mandating further time and resource-intensive investigations. Objective: To determine whether low basal dehydroepiandrosterone sulfate (DHEAS) is a sensitive and specific screening test for SH in AI. Setting and Patients: In total, 185 patients with AI were screened for adrenal medullary (plasma metanephrines) and cortical [1 mg overnight dexamethasone suppression test (ONDST), 24-hour urinary free cortisol (UFC), serum DHEAS, plasma renin, and aldosterone] hyperfunction. Positive ONDST [>= 1.8 mcg/dL(>= 50 nmol/L)] and/or UFC (more than the upper limit of reference range) results were further investigated. We diagnosed SH when at least 2 of the following were met: raised UFC, raised midnight serum cortisol, 48-hour dexamethasone suppression test (DST) cortisol >= 1.8 mcg/dL (>= 50 nmol/L). Results: 29 patients (16%) were diagnosed with SH. Adrenocorticotropin was, < 10pg/mL(<2.2pmol/L) in all patients with SH. We calculated age- and sex-specific DHEAS ratios (derived by dividing the DHEAS by the lower limit of the respective reference range) for all patients. Receiver operating characteristic curve analyses demonstrated that a ratio of 1.12 was sensitive (>99%) and specific (91.9%) for the diagnosis of SH. Cortisol following 1 mg ONDST of 1.9 mcg/dL (53 nmol/L) was a sensitive (>99%) screening test for SH but had lower specificity (82.9%). The 24-hour UFC lacked sensitivity (69%) and specificity (72%). Conclusion: A single basal measurement of DHEAS offers comparable sensitivity and greater specificity to the existing gold-standard 1mg DST for the detection of SH in patients with AIs.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available