4.6 Article

Determination of endogenous brassinosteroids using sequential magnetic solid phase extraction followed by in situ derivatization/desorption method coupled with liquid chromatography-tandem mass spectrometry

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1446, Issue -, Pages 103-113

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2016.04.012

Keywords

Brassinosteriod; Sequential MSPE; In situ derivatization/desorption; LC-MS/MS

Funding

  1. National Natural Science Foundation of China [91217309, 21475098]
  2. Natural Science Foundation of Hubei Province, China [2014CFA002]

Ask authors/readers for more resources

In this study, a sequential magnetic solid phase extraction followed by in situ derivatization/desorption method was proposed for the fast, selective and sensitive determination of brassinosteroids (BRs) in plant tissues. Magnetic sorbent for quick, easy, cheap, effective, rugged and safe method (mQuEChERS) and polymer(4-vinylphenylboronic acid-co-ethylene glycol dimethacrylate) coated Fe3O4@SiO2 (P(4-VPBA-co-EGDMA) coated Fe3O4@SiO2) were prepared and characterized. Using them as sorbents, pigments and hydrophilic interferents were firstly removed from plant extract by mQuEChERS, and then endogenous BRs were selectively enriched by p(4-VPBA-co-EGDMA) coated Fe3O4@SiO2 through boronate affinity interaction. After loading BRs on p(4-VPBA-co-EGDMA) coated Fe3O4@SiO2, instead of directly eluting free BRs, the adsorbed BRs were released by adding 4-(N,N-dimethyamino)phenylboronic acid (4-DMAPBA) solution for in situ derivatizaiton/desorption of BRs based on a transesterification reaction between the boronate moieties of p(4-VPBA-co-EGDMA) coated Fe3O4@SiO2 and 4-DMAPBA, finally the resultant solution was submitted to LC-MS/MS for quantification. The whole procedure of the sequential MSPE could be accomplished within 1 h, and the matrix effect to MS signal after the sample pretreatment was estimated to be in the range of 93.0-97.4%. The established method provided broad linear dynamics ranges (1.0-100.0 pg/mL) with correlation coefficients (R) >0.9978, substantial sensitivity (limits of detection ranged from 0.27 to 1.29 pg/mL), high reproducibility (intra-day and inter-day relative standard deviations (RSDs) less than 14.8%) and satisfactory accuracy (recoveries ranged from 74.0%-116.6%). Furthermore, endogenous BRs were successfully detected in one flower of Brassica napus L (22.5-542.7 pg/g fresh weight) and other plant tissues (13.7-289.8 pg/g fresh weight). (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available