4.6 Article

Estimation of an image derived input function with MR-defined carotid arteries in FDG-PET human studies using a novel partial volume correction method

Journal

JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM
Volume 37, Issue 4, Pages 1398-1409

Publisher

SAGE PUBLICATIONS INC
DOI: 10.1177/0271678X16656197

Keywords

Positron emission tomography; MRI; kinetic modelling; brain imaging; carotid artery

Funding

  1. Department of Health's NIHR Biomedical Research Centres funding scheme
  2. IMPACT - Siemens
  3. UCL Faculty of Engineering Sciences
  4. EPSRC [EP/K005278/1]
  5. EPSRC [EP/K005278/1] Funding Source: UKRI
  6. Engineering and Physical Sciences Research Council [EP/K005278/1] Funding Source: researchfish

Ask authors/readers for more resources

Kinetic analysis of F-18-fluorodeoxyglucose positron emission tomography data requires an accurate knowledge the arterial input function. The gold standard method to measure the arterial input function requires collection of arterial blood samples and is an invasive method. Measuring an image derived input function is a non-invasive alternative but is challenging due to partial volume effects caused by the limited spatial resolution of the positron emission tomography scanners. In this work, a practical image derived input function extraction method is presented, which only requires segmentation of the carotid arteries from MR images. The simulation study results showed that at least 92% of the true intensity could be recovered after the partial volume correction. Results from 19 subjects showed that the mean cerebral metabolic rate of glucose calculated using arterial samples and partial volume corrected image derived input function were 26.9 and 25.4mg/min/100g, respectively, for the grey matter and 7.2 and 6.7mg/min/100g for the white matter. No significant difference in the estimated cerebral metabolic rate of glucose values was observed between arterial samples and corrected image derived input function (p>0.12 for grey matter and white matter). Hence, the presented image derived input function extraction method can be a practical alternative to noninvasively analyze dynamic F-18-fluorodeoxyglucose data without the need for blood sampling.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available