4.4 Article

How renovation activities may jeopardise indoor air quality: accounting for short and long-term symptoms of sick building syndrome in educational buildings

Journal

ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT
Volume 19, Issue 4, Pages 360-377

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/17452007.2022.2060932

Keywords

Building renovation; indoor air quality; LEED; sick building syndrome; volatile organic compounds

Ask authors/readers for more resources

The study discusses the negative impact of building renovation on Indoor Air Quality (IAQ) and the symptoms of Sick Building Syndrome (SBS). Through site inspection, lab tests, and surveys, it was found that the pollutants produced during renovation exceeded international standards, posing health risks. The survey also revealed that SBS symptoms were more severe in poorly ventilated areas. The study recommends proper planning for IAQ during all stages of building renovation.
The study discussed how building renovation activities jeopardised Indoor Air Quality (IAQ) and caused several symptoms of Sick Building Syndrome (SBS). This postulation was investigated on a case study-renovated university building with different types of functional spaces. The research method comprised: (1) site inspection for renovation best practices, (2) Gas Chromatography lab tests to examine the types of pollutants (volatile organic compounds) caused by different types of finishing and comparing them to the international standards provided by the Leadership in Energy and Environmental Design (LEED), and finally (3) occupants' survey (labourers, staff and students) with variations in the magnitude and duration of their exposure to pollutants. The result of the lab tests exceeded the maximum threshold set by the LEED system which indicated a health risk. This was confirmed by the survey results showing associated symptoms of SBS during and after the renovation process noting that the symptoms escalated in confined places with poor ventilation. The conclusion indicated that material selection and renovation best practices were responsible for several health risks. Associated symptoms of SBS increased due to early occupancy and continued for three months after renovation completion. Eventually, the study recommended proper planning for IAQ during building renovation noting the interplay of causes and consequences of SBS: (1) during building renovation, (2) after completion, (3) before occupancy and (4) after at least one year of building operation. Further, it presented a set of recommendations for each phase across different project phases for the benefit of academic and industry outreach.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available