4.5 Review

Measured and perceived indoor air quality in three low-energy wooden test buildings

Journal

WOOD MATERIAL SCIENCE & ENGINEERING
Volume 18, Issue 3, Pages 827-840

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/17480272.2022.2077657

Keywords

Indoor air quality; perceived air quality; VOC; emissions; wood materials; low-energy buildings

Ask authors/readers for more resources

Stricter energy efficiency requirements of buildings have raised concerns about their effects on indoor air quality (IAQ). We studied measured and perceived IAQ in three low-energy wooden test buildings using different ventilation levels. The results show that increasing ventilation can reduce VOC concentrations and decrease dissatisfaction with air quality. However, buildings made of pinewood had higher VOC levels but lower dissatisfaction in certain ventilation conditions.
Stricter energy efficiency requirements of buildings have raised concerns about their effects on indoor air quality (IAQ). We studied measured arid perceived IAQ in three low-energy wooden test buildings using three ventilation levels (0.5, 1.0, and 2.0 (dm(3)/s)/m(2)). IAQ measurements included VOC (volatile organic compounds) air sampling and continuous measurements of several IAQ indicators. Perceived air quality (PAQ) was investigated with a sensory panel of untrained volunteers. The results show that the TVOC (Total VOC) concentrations were relatively low in two of the buildings already at the beginning of the study (100-141 mu g/m(3)), and the concentrations decreased in all test buildings when ventilation was increased from the lowest level. The third building made of pinewood timber showed higher VOC concentrations (340-857 mu g/m(3)), especially for terpene compounds that are generally present in pinewood emissions. In the PAQ assessment, the percentage of people dissatisfied (PD) with the air quality decreased with increased ventilation in all studied buildings. However, at the lowest and highest ventilation, the pinewood building had the second-lowest PD despite higher VOC levels. The findings of this study can be utilized in interpreting the effects of ventilation design and material selection on IAQ in low-energy buildings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available