4.5 Article

A Microphysiometric System Based on LAPS for Real-Time Monitoring of Microbial Metabolism

Journal

CHEMOSENSORS
Volume 10, Issue 5, Pages -

Publisher

MDPI
DOI: 10.3390/chemosensors10050177

Keywords

microphysiometer; LAPS; pH measurement; biosensor; microbial metabolism

Funding

  1. National Natural Science Foundation of China [62120106004]
  2. National Key Research and Development Program of China [2021YFF1200803, 2021YFB3200801, SQ2021AAA010032]
  3. Natural Science Foundation of Zhejiang Province [LBY21H180001, LY21C100001]
  4. China Postdoctoral Science Foundation Funded Project [2020M671728, 2021T140605]

Ask authors/readers for more resources

This article introduces a new method for microbial metabolism detection. By using a light addressable potentiometric sensor (LAPS) and a microfluidic LAPS chip, the decrease in pH caused by glucose fermentation in Lactobacillus rhamnosus was successfully measured. This method has the potential to be applied in metabolism detection of microorganisms and even 3D cells and organoids.
Macronutrients (carbohydrates, fat and protein) are the cornerstones of daily diet, among which carbohydrates provide energy for the muscles and central nervous system during movement and exercise. The breakdown of carbohydrates starts in the oral cavity, where they are primarily hydrolyzed to glucose and then metabolized to organic acids. The end products may have an impact on the oral microenvironment, so it is necessary to monitor the process of microbial metabolism and to measure the pH change. Although a pH meter has been widely used, it is limited by its sensitivity. We then introduce a light addressable potentiometric sensor (LAPS), which has been used in extracellular acidification detection of living cells with the advantages of being objective, quantitative and highly sensitive. However, it is difficult to use in monitoring bacterial metabolism because bacteria cannot be immobilization on the LAPS chip as easily as living cells. Therefore, a microphysiometric system integrated with Transwell insert and microfluidic LAPS chip was designed and constructed to solve this problem. The decrease in pH caused by glucose fermentation in Lactobacillus rhamnosus was successfully measured by this device. This proves the feasibility of the system for metabolism detection of non-adhere targets such as microorganisms and even 3D cells and organoids.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available