4.6 Article

Ten-Hour Stable Noninvasive Brain-Computer Interface Realized by Semidry Hydrogel-Based Electrodes

Related references

Note: Only part of the references are listed.
Article Neuroimaging

Lying posture affects sleep structures and cortical activities: a simultaneous EEG-fMRI imaging of the sleeping and waking brain

Dan Xu et al.

Summary: The study found that lying posture preference and position can affect sleep onset latency and duration of sleep stages, leading to alterations in brain activity patterns. Different sleep positions also influenced brain activity in specific regions, with individuals who prefer supine posture showing higher activity in the right putamen during wakefulness.

BRAIN IMAGING AND BEHAVIOR (2021)

Article Engineering, Biomedical

Doubling the Speed of N200 Speller via Dual-Directional Motion Encoding

Dingkun Liu et al.

Summary: A novel dual-directional N200 speller was developed in this study, achieving an average ITR of 79.8 bits/min and doubling the speed of the traditional uni-directional N200 speller. Online experiments demonstrated a maximum ITR of 124.8 bits/min, making it a promising candidate for fast and reliable BCI applications.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2021)

Article Engineering, Electrical & Electronic

An electrically conductive silver-polyacrylamide-alginate hydrogel composite for soft electronics

Yunsik Ohm et al.

Summary: The silver-hydrogel composite exhibits a high electrical conductivity of over 350 S cm(-1) and a low Young's modulus of less than 10 kPa. It demonstrates soft compliance and deformability, making it suitable for various applications such as stingray-inspired swimmers and neuromuscular electrical stimulation electrodes.

NATURE ELECTRONICS (2021)

Article Multidisciplinary Sciences

High-performance brain-to-text communication via handwriting

Francis R. Willett et al.

Summary: BCIs can restore communication for individuals with paralysis by decoding attempted handwriting movements, achieving typing speeds of 90 characters per minute with high accuracy. This approach opens new possibilities for BCIs and demonstrates the feasibility of decoding rapid, dexterous movements even years after paralysis.

NATURE (2021)

Article Computer Science, Artificial Intelligence

A Self-Paced BCI With a Collaborative Controller for Highly Reliable Wheelchair Driving: Experimental Tests With Physically Disabled Individuals

Aniana Cruz et al.

Summary: This article introduces a self-paced P300-based brain-computer interface control solution combined with dynamic time-window commands and a collaborative controller for brain-controlled wheelchairs. The proposed approach achieved high driving accuracy in experiments and received positive feedback from users, indicating potential usability improvements for BCWs in home settings.

IEEE TRANSACTIONS ON HUMAN-MACHINE SYSTEMS (2021)

Article Multidisciplinary Sciences

A brain-computer interface that evokes tactile sensations improves robotic arm control

Sharlene N. Flesher et al.

Summary: By using prosthetic arms controlled by a brain-computer interface and supplementing vision with tactile feedback, individuals with tetraplegia showed substantial improvement in performance. Mimicking known biological control principles resulted in task performance closer to able-bodied human abilities.

SCIENCE (2021)

Article Cell Biology

MXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation

Nicolette Driscoll et al.

Summary: MXtrodes are a class of soft, high-resolution, large-scale bioelectronic interfaces enabled by Ti3C2 MXene and scalable solution processing. They exhibit superior electro-chemical properties compared to conventional materials, do not require conductive gels, and have been validated in various applications.

SCIENCE TRANSLATIONAL MEDICINE (2021)

Article Multidisciplinary Sciences

Ultra-conformal skin electrodes with synergistically enhanced conductivity for long-time and low-motion artifact epidermal electrophysiology

Yan Zhao et al.

Summary: A study introduces an ultra-thin dry epidermal electrode that conforms to the skin, accurately measures electrophysiological signals, and exhibits low sheet resistance, high transparency, and mechano-electrical stability. The enhanced optoelectronic performance is attributed to the synergistic effect between graphene and PEDOT:PSS, allowing for the accurate monitoring of electrophysiological signals in humans with reduced motion artifact interference.

NATURE COMMUNICATIONS (2021)

Article Engineering, Biomedical

A Novel Bristle-Shaped Semi-Dry Electrode With Low Contact Impedance and Ease of Use Features for EEG Signal Measurements

Kun-Peng Gao et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2020)

Article Engineering, Biomedical

Incorporation of dynamic stopping strategy into the high-speed SSVEP-based BCIs

Jing Jiang et al.

JOURNAL OF NEURAL ENGINEERING (2018)

Article Chemistry, Analytical

Towards gel-free electrodes: A systematic study of electrode-skin impedance

Guangli Li et al.

SENSORS AND ACTUATORS B-CHEMICAL (2017)

Article Engineering, Biomedical

Enhancing P300-BCI performance using latency estimation

Md Rakibul Mowla et al.

BRAIN-COMPUTER INTERFACES (2017)

Article Chemistry, Analytical

Novel passive ceramic based semi-dry electrodes for recording electroencephalography signals from the hairy scalp

Guangli Li et al.

SENSORS AND ACTUATORS B-CHEMICAL (2016)

Article Mathematical & Computational Biology

Driving a Semiautonomous Mobile Robotic Car Controlled by an SSVEP-Based BCI

Piotr Stawicki et al.

COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE (2016)

Article Multidisciplinary Sciences

Soft, curved electrode systems capable of integration on the auricle as a persistent brain-computer interface

James J. S. Norton et al.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2015)

Article Multidisciplinary Sciences

High-speed spelling with a noninvasive brain-computer interface

Xiaogang Chen et al.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2015)

Article Engineering, Biomedical

Usability of four commercially-oriented EEG systems

W. David Hairston et al.

JOURNAL OF NEURAL ENGINEERING (2014)

Review Chemistry, Analytical

Dry EEG Electrodes

M. A. Lopez-Gordo et al.

SENSORS (2014)

Article Engineering, Biomedical

Analysis and classification of speech imagery EEG for BCI

Li Wang et al.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2013)

Article Engineering, Biomedical

Offline analysis of context contribution to ERP-based typing BCI performance

Umut Orhan et al.

JOURNAL OF NEURAL ENGINEERING (2013)

Article Clinical Neurology

A comparison of recording modalities of P300 event-related potentials (ERP) for brain-computer interface (BCI) paradigm

L. Mayaud et al.

NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY (2013)

Article Cell Biology

Translating the Brain-Machine Interface

Nitish V. Thakor

SCIENCE TRANSLATIONAL MEDICINE (2013)

Article Neurosciences

Comparison of dry and gel based electrodes for P300 brain-computer interfaces

Christoph Guger et al.

FRONTIERS IN NEUROSCIENCE (2012)

Article Engineering, Biomedical

Frequency and Phase Mixed Coding in SSVEP-Based Brain-Computer Interface

Chuan Jia et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2011)

Article Engineering, Biomedical

BCI Demographics: How Many (and What Kinds of) People Can Use an SSVEP BCI?

Brendan Allison et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2010)

Review Neurosciences

Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives

Francois-Benoit Vialatte et al.

PROGRESS IN NEUROBIOLOGY (2010)

Article Neurosciences

How many people are able to control a P300-based brain-computer interface (BCI)?

Christoph Guger et al.

NEUROSCIENCE LETTERS (2009)

Editorial Material Engineering, Biomedical

BCI Meeting 2005 - Workshop on clinical issues and applications

A. Kuebler et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2006)

Article Clinical Neurology

Evaluation of commercially available electrodes and gels for recording of slow EEG potentials

P Tallgren et al.

CLINICAL NEUROPHYSIOLOGY (2005)

Article Engineering, Biomedical

How many people are able to operate an EEG-based brain-computer interface (BCI)?

C Guger et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2003)

Article Engineering, Biomedical

A BCI-based environmental controller for the motion-disabled

XR Gao et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2003)

Article Engineering, Biomedical

Design and implementation of a brain-computer interface with high transfer rates

M Cheng et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2002)

Article Engineering, Biomedical

Real-time EEG analysis with subject-specific spatial patterns for a brain-computer interface (BCI)

C Guger et al.

IEEE TRANSACTIONS ON REHABILITATION ENGINEERING (2000)