4.7 Article

Physicochemical Profile of Antiandrogen Drug Bicalutamide: Solubility, Distribution, Permeability

Journal

PHARMACEUTICS
Volume 14, Issue 3, Pages -

Publisher

MDPI
DOI: 10.3390/pharmaceutics14030674

Keywords

bicalutamide; solubility; Hansen parameter; distribution coefficient; thermodynamic approach

Funding

  1. State Program of Fundamental Scientific Research [AAAA-A21-121011590019-8]

Ask authors/readers for more resources

The pharmacologically relevant physicochemical properties of the antiandrogen drug bicalutamide (BCL) were determined for the first time. The study found that BCL had low solubility in water and n-hexane, but higher solubility in alcohols. Thermodynamic analysis showed that BCL preferred lipophilic delivery pathways in biological media.
The pharmacologically relevant physicochemical properties of the antiandrogen drug bicalutamide (BCL) have been determined for the first time. Solubility in aqueous solution, 1-octanol, n-hexane, and ethanol was measured by the shake flask method in the temperature range of 293.15-313.15 K. The compound was shown to be poorly soluble in aqueous medium and n-hexane; at the same time, an essentially higher solubility in the alcohols was revealed. The following order of molar solubility was determined: ethanol > 1-octanol > water approximate to n-hexane. The solubility was correlated with the Van't Hoff and Apelblat equations. Evaluation of the Hansen solubility parameters and the atomic group contribution approach of Hoftyzer and Van Krevelen demonstrated consistency with the experimental data and good potential adsorption of bicalutamide. The temperature dependences of the distribution coefficients in the 1-octanol/water and n-hexane/water two-phase systems were measured and discussed in the framework of the thermodynamic approach. The increment logD parameter determined from the distribution experiment clearly demonstrated the preference of the lipophilic delivery pathways for the compound in the biological media. The overall thermodynamic analysis based on the solubility and distribution results of the present study and the sublimation characteristics published previously has been performed. To this end, the thermodynamic parameters of the dissolution, solvation, and transfer processes were calculated and discussed in view of the solute-solvent interactions. The permeation rate of BCL through the PermeaPad barrier was measured and compared with PAMPA permeability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available